Specifications
|
ELECTRICAL
|
3-Pole Measurement
|
Range (Auto-Ranging)
|
0.09 to 99.9k Ohms
|
Resolution
|
0.01 to 100 Ohms
|
Test Voltage / Current
|
Nominal 16 or 32 Volts RMS user selectable; Up to 250 milliAmps
|
Resistance Measurement Frequency
|
41 to 5078 Hertz user selectable or automatic selection
|
Accuracy
|
±2 percent of Reading + 1ct at 128 Hertz
|
Earth Coupling Measurement
|
Yes
|
4-Pole Measurement
|
Range (Auto-Ranging)
|
0.001 to 99.99k Ohms
|
Resolution
|
0.001 to 10 Ohms
|
Test Voltage
|
16 or 32 Volts user selectable
|
Resistance Measurement Frequency
|
From 41 to 5078 Hertz selectable
|
Accuracy
|
±2 percent of Reading + 1cts at 128 Hertz
|
NOTE
|
4 Pole Measurement with 1 Clamp SR182 (same specification as the 4 Pole measurement) 4 Pole Measurement with 1 Clamp MN182 (same specification as the 4 Pole measurement + 5 percent)
|
2 Clamp Measurement
|
Range (Auto-Ranging)
|
0.01 to 500 Ohms
|
Resolution
|
0.01 to 1 Ohms
|
Frequency
|
128, 1367, 1611, 1758 Hertz
|
Accuracy with SR182
|
±10 percent of Reading + 1cts
|
Accuracy with MN182
|
±20 percent of Reading + 2cts
|
Soil Resistivity 4 Pole Measurement
|
Test Method
|
Wenner or Schlumberger selectable with automatic calculation
of test results in Ohm-meters, Ohm-cm or Ohm-feet
|
Range (Auto-Ranging)
|
0.01 to 99.99k ohms; P Max: 999kOhmsm (display in kOhmft is not possible)
|
Resolution
|
0.01 to 100 Ohms
|
Test Voltage
|
16 or 32 Volts user selectable
|
Frequency
|
From 41 to 128 Hertz selectable
|
Accuracy
|
±2 percent of Reading + 1cts
|
Earth Potential Measurement
|
Range (Auto-Ranging)
|
0.01 mV to 65 Volt
|
Resolution
|
0.01 to 10 mV
|
Accuracy
|
±2 percent of Reading + 1ct at 128 Hertz
|
Frequency
|
From 41 to 128 Hertz selectable
|
Accuracy
|
2 percent of Reading + 1cts
|
External Voltage Measurement
|
Range (Auto-Ranging)
|
0.1 to 65.0 Volts AC/DC – DC to 440 Hertz
|
Accuracy
|
±2 percent of Reading + 1cts
|
Input Impedance
|
1.2M Ohms
|
External Current Measurement
|
Range (Auto-Ranging) with SR182
|
0.01 to 40.0 Amps – 16 to 400 Hertz
|
Accuracy at 50 to 99Hz
|
±5 percent of Reading + 2cts from 0.01 to 100mA; ±10 percent + 2cts from 0.1 to 40A
|
Range (Auto-Ranging) with MN182
|
0.01 to 9.99A – 16 to 400 Hertz
|
Accuracy at 50 to 99Hz
|
±7 percent of Reading + 2cts from 0.01 to 100mA; ±15 percent + 2ctsfrom 0.1 to 10A
|
Resistance Measurement (Bond Testing) IEC 61557/4
|
Measurement Type
|
2 Pole (with lead resistance compensation) or 4 Pole (Kelvin sensing) user selectable
|
Range (Auto-Ranging)
|
2 Pole 0.01 to 99.9k Ohms; 4-Pole 0.001 to 99.99k Ohms
|
Accuracy
|
±2 percent of Reading + 2cts
|
Test Voltage / Current
|
16 V dcdc (+, - or auto polarity); Up to 250mA max
|
Data Storage
|
Memory Capacity
|
512 test results
|
Communication
|
Optically Isolated USB
|
Automatic Report Generation
|
Yes — Tabular listings, Fall-of-Potential plots and Frequency/Resistance plots
|
Power Source
|
9.6 Volt rechargeable battery pack
|
Recharging Source
|
110/220 50/60Hz external charger with 18Vdcdc, 1.9A output or 12 Volt vehicle power
|
MECHANICAL
|
Test Lead Connection
|
4 millimeter recessed banana jacks
|
Mechanical Shock
|
Per EN 61557
|
Vibration Test
|
Per EN 61557
|
Drop Test
|
Per EN 61557
|
Dielectric Test
|
3kV 50/60Hz
|
Dimensions
|
10.7 x 9.76 x 5.12 inches
272 x 248 x 130 millimeters
|
Weight
|
7.5 pounds (3.5 kg)
|
Case
|
Polypropylene
|
Index of Protection
|
IP53 with cover closed
|
DISPLAY
|
Display Type
|
Custom 256 segment multi-line LCD
|
Backlight
|
Blue electroluminescent
|
COMMUNICATION
|
Software
|
DataViewgraphing, analysis and reporting software
|
ENVIRONMENTAL
|
Operating Temperature
|
14 to 122 degrees F
-10 to 55 degrees C)
|
Storage Temperature
|
-40 to 158 degrees F
-40 to 70 degrees C
|
SAFETY
|
Safety Rating
|
EN61010-1 50V Cat IV, Pollution Degree 2
|
Double Insulation
|
Yes
|
CE Mark
|
Yes
|