Operating Modes |
Model |
iX Series II
|
i Series II
|
Modes |
AC, DC or AC+DC
|
AC or DC
|
AC Output Mode |
Frequency |
Range: 16.00-1000 Hz (Note: Voltage on 300 V range derates from 300 Vrms max at 500 Hz to 150 Vrms max at 1000 Hz; See V-F rating chart. below) |
Total Power |
3001i/iX: 3000 VA, 5001i/iX: 5000 VA, 9003i/iX: 3000 VA 3ø, with mode iX: 9000 VA 1ø, 10001i/iX: 10000 VA, 15001i/iX: 15000
VA, 15003i/iX: 5000 VA/ø 3ø, with mode iX: 15000 VA/ø 1ø |
Load Power Factor |
0 to unity at full output VA |
AC Voltage Mode |
Voltage Ranges
Output Noise
(20 kHz to 1 MHz) |
Range
|
VLow
|
VHigh
|
AC
|
0-150 V
|
0-300 V
|
AC+DC
|
0-150 V
|
0-300 V
|
Load Regulation
(with ALC on)
|
< 0.2%
|
Load Regulation
(with ALC off)
|
< 0.5% DC to 100 Hz,
< 0.6% 100 Hz to 500 Hz in high voltage range,
< 2.2% 100 Hz to 500 Hz in low voltage range,
< 3% 500 Hz to 1000 Hz
|
Line Regulation
|
< 0.1% for 10% line change
|
< 250 mVrms typ., < 500 mVrms max. |
Harmonic Distortion (Linear) |
< 1% from 16 - 66 Hz, < 2% at 400 Hz, < 3% at 800 Hz (Full resistive load) |
DC Offset |
< 20 mV External Amplitude Modulation: Depth: 0 - 10 %, Frequency: DC - 2 KHz |
Isolation Voltage |
300 Vrms output to chassis |
AC Mode Current |
Model |
Model
|
3001 i/iX
|
5001 i/iX
|
9003 i/iX 3ø
|
Steady State AC Current |
300 V range
|
11.1
|
18.5
|
11.1 /ø
|
|
150 V range
|
22.2
|
37.0
|
22.2 /ø
|
Note: Constant power mode provides increased current at reduced voltage (See chart below) |
Model |
Model
|
10001 i/iX
|
15001 i/iX
|
15003 i/iX 3ø
|
Steady State AC Current |
300 V range
|
37.0
|
55.5
|
18.5 /ø
|
|
150 V range
|
74.0
|
111.0
|
37.0 /ø
|
Note: Constant power mode provides increased current at reduced voltage (See chart below) |
Model |
Model
|
3001 i/iX
|
5001 i/iX
|
9003 i/iX 3ø
|
Peak Repetitive AC Current |
High range
|
96.0
|
96.0
|
96.0 /ø
|
|
Low range
|
110.0
|
110.0
|
110.0 /ø
|
Model |
Model
|
10001 i/iX
|
15001 i/iX
|
15003 i/iX 3ø
|
Peak Repetitive AC Current |
High range
|
192.0
|
288.0
|
96.0 /ø
|
|
Low range
|
220.0
|
330.0
|
110.0 /ø
|
Programming Accuracy |
Voltage (rms): ± 0.2 of range, 16 to 1000 Hz, Frequency: ± 0.01 % of programmed value, Current Limit: ± 0.5 % of programmed value, Phase: < 1.5° with balanced load at 50/60 Hz |
Programming Resolution |
Voltage (rms): 100 mV, Frequency: 0.01 Hz from 16 - 81.91 Hz, 0.1 Hz from 82.0 - 819.1 Hz, 1 Hz from 820-1000 Hz, Current Limit: 0.1 A, Phase, 0.1° |
Output Relay |
Push-button controlled or bus controlled output relay |
Output Impedance (iX Only) |
Programmable Z on 3001iX, 5001iX, 9003iX and 15003iX (3ø mode only) for 50 Hz fundamental |
Resistive |
Range: 17 - 1000 mOhm,resolution: 4 mOhm accuracy, 2 % FS |
Inductive |
Range: 230 - 1000 μH, resolution: 4 μH, accuracy: 2 % FS |
Measurements - Standard (AC Measurements) |
Parameter |
Frequency
|
RMS Voltage
|
RMS Current
|
Peak Current
|
Range |
16-500 Hz
|
0-300 V
|
0-40 A
|
0-120 A
|
Accuracy* (±)
0.01% +
0.01 Hz |
< 100 Hz
100 - 500 Hz |
0.5 V + 0.02%
0.1 V + 0.02% |
0.5 A + 0.02%
0.1 A + 0.02% |
0.5 A + 0.02%
0.1 A + 0.02% |
Resolution* |
0.01 Hz
|
10 mV
|
1 mA
|
1 mA
|
Parameter |
Crest Factor
|
Real Power
|
Apparent Pwr
|
Pwr Factor
|
Range |
0.00-6.00
|
0-6 kW
|
0-6 kVA
|
0.00-1.00
|
Accuracy* (±)
0.01% +
0.01 Hz |
0.05
0.05 |
10 W + 0.1%
20 W + 0.1% |
10 VA + 0.1%
20 VA + 0.1% |
0.01
0.02 |
Resolution* |
0.01
|
1 W
|
1 VA
|
0.01
|
Parameter |
DC Voltage
|
DC Current
|
Power
|
|
Voltage Ranges |
0-300 V
|
0-40 A
|
0-6 kW
|
|
Accuracy* (±)
0.01% +
0.01 Hz |
150 mV
150 mV |
70 mA
70 mA |
15 W
15 W |
|
Resolution* |
10 mV
|
1 mA
|
1 W
|
|
* Measurement system bandwidth = DC to 48 kHz. Accuracy specifications are valid above 100 counts. Current and Power Accuracy specifications are times two for 10001i/iX /30003i/iX and times three for 15001i/iX and 9003i/iX and 15003i/iX with MODE-iX option when in single phase mode. For 10001i/iX, 15001i/iX and 30003i/ iX, resolution decreases by factor of 10, ranges for current and power increases by factor of three. PF accuracy applies for PF > 0.5 and VA > 50% of range. |
Measurements - Harmonics |
Parameter |
Frequency Fundamental Harmonics
|
Phase
|
Voltage
|
Current
|
Range |
16.00-500.0 Hz / 32.00 Hz - 48.00 kHz
|
0.0 - 360.0°
|
Fundamental Harmonics 2 - 50
|
Fundamental Harmonics 2 - 50
|
Accuracy* (±) |
0.01% + 0.01 Hz
|
2° typ.
|
250 mV 0.1% + 250 mV+0.1% /1 kHz
|
50 mA/0.1% + 50 mA +0.1% /1 kHz
|
Resolution |
0.01 Hz
|
0.5°
|
10 mV / 10 mV
|
10 mA / 10 mA
|
* Accuracy specifications are valid above 100 counts. Accuracy specifications are times three for three phase mode. Harmonics frequency range in three phase mode is 32 Hz - 16 kHz. Resolution decreases by factor of 10 for 9003iX and 15003iX with Mode-iX option in 1 phase mode and for 10001iX, 15001iX and 30003i/iX. |
DC Mode Output |
Power (Max at full scale of DC Voltage Range) |
3001i/iX: 2100 W, 5001i/iX: 3500 W, 9003i/iX: 2100 W/ø 3ø, 6300 W/ø 1ø, 10001i/iX: 7000 W, 15001i/iX: 10500 W, 15003i/iX: 3500 W/ø 3ø, 10500 W/ø 1ø |
Voltage Ranges |
Range: Low: 200 Vdc, High: 400 Vdc |
Line Regulation |
< 0.1% FS or 10% line change |
Output Noise |
< 250 mV rms typ., < 500 mV rms max., (20 kHz to 1 MHz) |
Max DC Current (Maximum current at 65% of V Range) |
Model |
3001 i/iX
|
5001 i/iX
|
9003 i/iX
|
9003 i/iX 3ø
|
400V range |
7.8
|
13
|
23.4
|
7.8
|
200V range |
15.6
|
26
|
46.8
|
15.6
|
Model |
10001 i/iX
|
15001 i/iX
|
15003 i/iX 3ø
|
400V range |
26
|
39
|
13
|
200V range |
52
|
78
|
26
|
Current Limit |
Programmable from 0 A to maximum current for selected range |
AC+DC Mode Output |
Output Power (iX only) |
Full AC Power if DC component is less than 20% of full scale voltage, Full DC power if DC component is above 20% |
Storage |
Non Volatile Mem. storage |
16 instrument setups, 200 user defined waveforms |
Waveforms |
Waveform Types |
i Series II: Sine, iX Series II: Sine, Square, Clipped sine, User defined |
User defined waveform storage |
Four groups of 50 user defined arbitrary waveforms of 1024 points for a total of 200 (One group can be active at a time) |
System Interface |
Inputs |
Remote shutdown, External Sync, Clock/Lock (option) |
Outputs |
Function Strobe, Clock/Lock (option) |
Protection |
Over Load |
Constant Current or Constant Voltage mode |
Over Temperature |
Automatic shutdown |
Remote Control |
IEEE-488 Interface |
IEEE-488 (GPIB) talker listener. Subset: AH1, C0, DC1, DT1, L3, PP0, RL2, SH1, SR1, T6, IEEE-488.2 SCPI Syntax |
RS232C Interface |
9 pin D-shell connector, Handshake: CTS, RTS, Data bits: 7,8, Stop bits: 1, 2, Baud rate: 9600, 19200, 38400, 57600, 115200, IEEE-488.2 SCPI Syntax (Supplied with RS232C cable) |
DC Mode Output |
Voltage |
3001 and 9003: 208-240 ± 10% Vac, (L-N, 1ø), All other models: Standard: 208-240 ± 10% Vac, (L-L, 3ø), Option -400: 400-480 ± 10% Vac, (L-L, 3ø) (Input range must be specified when ordering) |
Max DC Current (Maximum current at 65% of V Range) |
Model |
3001i/iX
|
5001i/iX
|
9003i/iX
|
187-264V |
25 A
|
23 A
|
75 A
|
360-528V |
N/A
|
12 A
|
N/A
|
Model |
10001 i/iX
|
15001 i/iX
|
15003 i/iX 3ø
|
187-264V |
46 A
|
69 A
|
69 A
|
360-528V |
24 A
|
36 A
|
36 A
|
Inrush Current per chassis |
< 100 Apk for 100 μs at 208-240 V, < 50 Apk for 100 μs at 400-480 V |
Line Frequency |
50-60 Hz ± 10 % |
Efficiency |
75% typical |
Power Factor |
0.6 typical |
AC Service |
Regulatory |
IEC61010, EN50081-2, EN50082-2, CE EMC and Safety Mark requirements |
RFI Suppression |
CISPR 11, Group1 , Class A |
Rear Panel Connectors |
AC Input & Output terminal block with cover, IEEE-488 (GPIB) connector (rear panel), 9 pin D-Shell RS232C connector*, Remote voltage sense terminal block, System Interface Connector, *RS232 DB9 to DB9 cable supplied |
Physical Dimensions |
Dimensions |
Height: 7“ (178 mm), Width: 19“ (483 mm), Depth: 24“ (610 mm)
(depth includes rear panel connectors) |
Weight |
per 5001i/iX Chassis: Net: 61 lbs / 28 Kg, Shipping: 115 lbs / 52 Kg |
Vibration and Shock |
Designed to meet NSTA project 1A transportation levels |
Air Intake/Exhaust |
Forced air cooling, side air intake, rear exhaust. |
Operating Humidity |
0 to 95 % RAH, non condensing. |
Temperature |
Operating: 0 to 40° C, Storage: -20 to +85° C |