OUTPUT |
Voltage range |
Voltage range 0V to 330V AC/DC |
Voltage resolution |
0.025% (12 bit) |
Output frequency |
DC, 10Hz to 80Hz |
Frequency resolution |
0.02Hz |
Frequency accuracy, stability |
100ppm |
Output power |
2,000VA |
Output connector |
Safety laboratory connectors |
Output current, 50Hz |
Continuous: 7.7A maximum
RMS (max. 3s): 15.1A
Repetitive peak: 60A |
Output current, 60Hz |
Continuous: 8.0A maximum
RMS (max. 3s): 15.4A
Repetitive peak: 60A |
REGULATION |
Voltage Sense |
Internal or external, 4 wires |
Total harmonic distortion |
Less than 0.1% |
Output voltage stability |
Better than 0.1% |
Output voltage accuracy |
Better than 0.5% |
Max. compensatable drop on wires |
5% f.s. |
Protection |
Overcurrent
Overtemperature
Overvoltage
Undervoltage |
INPUT (VIA ISOLATION TRANSFORMER) |
Supply voltage |
230V (L,N,PE) |
Input current |
16A |
Line frequency |
45Hz to 65Hz |
Fuse |
16A internal |
Connector |
16A |
AMBIENT CONDITIONS |
Temperature |
0°C to 35°C |
Rel. humidity |
80%, non condensing |
CONTROL |
Interface |
RS 232 9-pin SubD for control via CWS 500N4 |
DIMENSIONS |
Housing |
19"", 6HU |
Weight |
23kg |
Size |
287mm x 449mm x 500mm |