RTCA DO-160 Section 22
RTCA DO-160 Section 22: Lightning Induced Transient Susceptibility
These test methods and procedures are provided to verify the capability of equipment to withstand a selection of test transients defined in this section which are intended to represent the induced effects of lightning.
The wave-forms and levels, and the pass/fail criteria for equipment performance during the test shall be listed in the applicable equipment specification.
Two groups of tests may be used for equipment qualification:
- The first is a damage tolerance test performed using pin injection
- The second group evaluates the functional upset tolerance of equipment when transients are applied to interconnecting cable bundles
- Pin test waveform set letter (A or B) as designated in Table 22-1.1 or Z or X
- Pin test level (1 to 5) as designated in Table 22-2 or Z or X
- Cable bundle single and multiple stroke test waveform set letter (C through K) as designated in Table 22-1.2 or Z or X
- Cable bundle single and multiple stroke test level (1 to 5) as designated in Table 22-3 and Table 22-4 or Z or X
- Cable bundle multiple burst test waveform set letter (L or M) as designated in Table 22-1.2 or Z or X
- Cable bundle multiple burst test level (1 to 5) as designated in Table 22-5 or Z or X