| Common |
| Meter Accuracy |
1% of full scale + 1 count |
| Max. Voltage Differential from Output to Safety Ground |
150 VDC |
| Remote Start/Stop and Interlock |
TTL compatible input or 12-250 VAC (12-130 VDC) or a contact closure |
| Cooling |
Internal fan, over temperature shutdown if internal heat sink exceeds set temperature |
| Remote Sense |
The maximum allowed sense line drop is 4V per line (2V on the DCS 8/10V 1 kW/1.2 kW models and 1V/line for all 3 kW models). Line drop subtracts from the maximum available output voltage at full rated power. |
| Remote Programming |
Enabled via external jumper on rear panel connector J3 |
| Overvoltage Protection |
Crowbar type adjustable from 5-110% of rated output using front panel control (local or remote program selectable via J3 jumper) |
| Remote Analog Programming Linearity |
±1% Accuracy: ±5% |
| Regulatory |
Certified to UL/CSA 61010 and IEC/EN 61010-1 CE Compliant (LVD and EMC directive) |
| Input: Voltage and Frequency |
| Output Power |
200 - 250 VAC
|
100 - 132 VAC
|
| 1.2kW |
single phase, 9A typical, 47- 63 Hz
|
single phase, 18A typical, 47-63 Hz, internal jumper selectable
|
| Output: Voltage and Current |
| 1.2kW Model |
Voltage
|
Current
|
| DCS 8-140E |
0 - 8
|
0 - 140
|
| DCS 10-120E |
0 - 10
|
0 - 120
|
| DCS 20-60E |
0 - 20
|
0 - 60
|
| DCS 33-36E |
0 - 33
|
0 - 36
|
| DCS 40-30E |
0 - 40
|
0 - 30
|
| DCS 50-24E |
0 - 50
|
0 - 24
|
| DCS 60-20E |
0 - 60
|
0 - 20
|
| DCS 80-15E |
0 - 80
|
0 - 15
|
| DCS 100-12E |
0 - 100
|
0 - 12
|
| DCS 150-8E |
0 - 150
|
0 - 8
|
| DCS 300-4E |
0 - 300
|
0 - 4
|
| Output |
| Voltage Resolution |
0.02% |
| Ripple (mV rms or p-p) |
See table |
| Regulation Line |
For input voltage variation over the AC input voltage range, with constant rated load. |
| Load |
For 0-100% load variation, with constant nominal line voltage. |
| Voltage |
0.1% |
| Current |
0.1% |
| Transient Response |
Typically recovers in 500 μs (1 & 1.2 kW) or 1ms (3k W) to 1% of steady-state output voltage (within 1% of Vmax) for 70-100% or 100-70% load change. |
| Stability |
±0.05% of maximum voltage or current over 8 hours after 30 minute warm-up time at fixed line, load and temperature |
| Efficiency |
See table below Temperature Coefficient: 0.02%/°C of maximum output voltage; 0.03%/°C of maximum output current. Change in output per °C change in ambient temperature, with constant line and load |
| Physical |
| Dimensions |
Width: 19“ (482 mm) W, Depth 17.52“ (445 mm)
Height: 1 kW and 1.2 kW: 1U or 1.72“ |
| Weight & Shipping Weight |
| Weight |
1 kW and 1.2 kW: 19 lbs. ( 8.6 kg) |
| Shipping Weight |
1 kW and 1.2 kW: 24 lbs. (10.9 kg) |
| Environmental |
| Operating Temperature |
0°C to 50°C (no derating) |
| Storage Temperature |
-55°C to 85°C |
| Humidity Range |
0 to 80% RH, non condensing |
| Programming Specifications |
| DCS Series 1.2 kW |
Programming Accuracy M130/M131/M9C/M85 Options
|
|
Voltage 0.1% +
|
Current 0.1% +
|
OVP 0.5% +
|
| DCS 8-140E |
8mV
|
560mA
|
44mV
|
| DCS 10-120E |
10mV
|
480mA
|
55mV
|
| DCS 20-60E |
20mV
|
240mA
|
110mV
|
| DCS 33-36E |
23mV
|
144mA
|
182mV
|
| DCS 40-30E |
40mV
|
120mA
|
220mV
|
| DCS 50-24E |
50mV
|
96mA
|
275mV
|
| DCS 60-20E |
60mV
|
80mA
|
330mV
|
| DCS 80-15E |
80mV
|
60mA
|
440mV
|
| DCS 100-12E |
100mV
|
48mA
|
550mV
|
| DCS 150-8E |
150mV
|
32mA
|
825mV
|
| DCS 300-4E |
300mV
|
16mA
|
1650mV
|
| Output |
| DCS Series 1.2 kW |
Output Power
|
|
Voltage VDC
|
Current ADC @ 50°C
|
| DCS 8-140E |
0-8
|
0-140
|
| DCS 10-120E |
0-10
|
0-120
|
| DCS 20-60E |
0-20
|
0-60
|
| DCS 33-36E |
0-33
|
0-36
|
| DCS 40-30E |
0-40
|
0-30
|
| DCS 50-24E |
0-50
|
0-24
|
| DCS 60-20E |
0-60
|
0-20
|
| DCS 80-15E |
0-80
|
0-15
|
| DCS 100-12E |
0-100
|
0-12
|
| DCS 150-8E |
0-150
|
0-8
|
| DCS 300-4E |
0-300
|
0-4
|
| Output |
| DCS Series 1.2 kW |
Constant Voltage Mode*
|
|
Ripple (rms) ** mV
|
Noise (p-p) mV
|
Transient Response
time μs (typ)
|
| DCS 8-140E |
5
|
60
|
500
|
| DCS 10-120E |
55
|
60
|
500
|
| DCS 20-60E |
5
|
60
|
500
|
| DCS 33-36E |
5
|
60
|
500
|
| DCS 40-30E |
5
|
60
|
500
|
| DCS 50-24E |
5
|
60
|
500
|
| DCS 60-20E |
5
|
60
|
500
|
| DCS 80-15E |
5
|
60
|
500
|
| DCS 100-12E |
10
|
60
|
500
|
| DCS 150-8E |
15
|
160
|
500
|
| DCS 300-4E |
25
|
200
|
500
|
| Output |
| DCS Series 1.2 kW |
Combined Regulation Line and Load %
|
Temp Coeff. Voltage %
|
Voltage Drift
% Vmax (typ)
|
| DCS 8-140E |
0.2
|
0.02
|
0.05
|
| DCS 10-120E |
0.2
|
0.02
|
0.05
|
| DCS 20-60E |
0.2
|
0.02
|
0.05
|
| DCS 33-36E |
0.2
|
0.02
|
0.05
|
| DCS 40-30E |
0.2
|
0.02
|
0.05
|
| DCS 50-24E |
0.2
|
0.02
|
0.05
|
| DCS 60-20E |
0.2
|
0.02
|
0.05
|
| DCS 80-15E |
0.2
|
0.02
|
0.05
|
| DCS 100-12E |
0.2
|
0.02
|
0.05
|
| DCS 150-8E |
0.2
|
0.02
|
0.05
|
| DCS 300-4E |
0.2
|
0.02
|
0.05
|
| Output |
| DCS Series 1.2 kW |
Constant Current Mode*
|
|
Regulation line and load % combined
|
Ripple (rms)** mA
|
| DCS 8-140E |
0.2
|
180
|
| DCS 10-120E |
0.2
|
153
|
| DCS 20-60E |
0.2
|
30
|
| DCS 33-36E |
0.2
|
11
|
| DCS 40-30E |
0.2
|
9
|
| DCS 50-24E |
0.2
|
8.5
|
| DCS 60-20E |
0.2
|
6.6
|
| DCS 80-15E |
0.2
|
6
|
| DCS 100-12E |
0.2
|
3.6
|
| DCS 150-8E |
0.2
|
2.3
|
| DCS 300-4E |
0.2
|
1.2
|
| Output |
| DCS Series 1.2 kW |
Input Current, A Nominal
|
Efficiency % (Typ.)
|
|
230V Single Phase
|
208V Three Phase
|
|
| DCS 8-140E |
9
|
N/A
|
82
|
| DCS 10-120E |
9
|
N/A
|
82
|
| DCS 20-60E |
9
|
N/A
|
82
|
| DCS 33-36E |
9
|
N/A
|
84
|
| DCS 40-30E |
9
|
N/A
|
84
|
| DCS 50-24E |
9
|
N/A
|
84
|
| DCS 60-20E |
9
|
N/A
|
85
|
| DCS 80-15E |
9
|
N/A
|
85
|
| DCS 100-12E |
9
|
N/A
|
85
|
| DCS 150-8E |
9
|
N/A
|
85
|
| DCS 300-4E |
9
|
N/A
|
85
|