| NETWAVE 20 | 
| Output voltage | 0 V 3*300 V AC (p-n)
0 V - +/- 425 V DC, (850 VDC*) | 
| Output current | 26 A (RMS) continuous
47 A (RMS) short term (max. 3 s) 200 A repetitive peak | 
| GENERAL DATA (ALL MODELS) | 
| SPECIFICATIONS | 
| Output frequency | DC - 5,000 Hz | 
| Frequency accuracy | 100 ppm | 
| Output connectors | Safety lab connectors
CEE type 32 A (only for NetWave 20.x and NetWave 30.x) | 
| Interfaces | GPIB
Ethernet
RS 232 (input from DPA analyser)
Frame bus (internal system bus) | 
| Phase accuracy | Resolution 1° | 
| Output noise | < 50 V: 110 mV rms
> 50 V: 320 mV rms | 
| Slew Rate | 8V/μs | 
| REGULATION | 
| Voltage sense | Internal or external, 4 wires | 
| Distortion (THD) | Less than 0. 5%, @50/60 Hz | 
| Output voltage Stability | Better than 0.1 % | 
| Output voltage Accuracy | Better than 0.5 % | 
| Max. compensable drop on wires | 5 % of V nominal | 
| Current limiter | 5 A to Imax
Stop / Continuous (behavior) | 
| Protection | Over current
Over voltage
Over temperature
Low voltage | 
| TRIGGER AND DUT MONITORING | 
| Trigger | 2 inputs, 2 outputs | 
| DUT monitors | 2 inputs, configurable | 
| OPTION FOR DC EXTENDED VOLTAGE RANGE | 
| * with option | OPT-3 DC-EVR,
Double the DC voltage |