Output Ratings |
Model |
Output Voltage¹
|
Output Current²
|
Output Power³
|
XG 6-110 |
6 V
|
110 A
|
670 W
|
XG 8-100 |
8 V
|
100 A
|
810 W
|
XG 12-70 |
12 V
|
70 A
|
850 W
|
XG 20-42 |
20 V
|
42 A
|
850 W
|
XG 33-25 |
33 V
|
25 A
|
835 W
|
XG 40-21 |
40 V
|
21 A
|
850 W
|
XG 60-14 |
60 V
|
14 A
|
850 W
|
XG 80-10.5 |
80 V
|
10.5 A
|
850 W
|
XG 100-8.5 |
100 V
|
8.5 A
|
860 W
|
XG 150-5.6 |
150 V
|
5.6 A
|
850 W
|
XG 300-2.8 |
300 V
|
2.8 A
|
850 W
|
XG 600-1.4 |
600 V
|
1.4 A
|
850 W
|
Line Regulation |
Model |
Voltage (0.005% of rated
output voltage +2 mV)4
|
Current (0.01% of rated
output current +2 mA)5
|
XG 6-110 |
2.3 mV
|
13 mA
|
XG 8-100 |
2.4 mV
|
12 mA
|
XG 12-70 |
2.6 mV
|
9 mA
|
XG 20-42 |
3.0 mV
|
6.2 mA
|
XG 33-25 |
3.7 mV
|
4.5 mA
|
XG 40-21 |
4 mV
|
4.1 mA
|
XG 60-14 |
5 mV
|
3.4 mA
|
XG 80-10.5 |
6 mV
|
3.1 mA
|
XG 100-8.5 |
7 mV
|
2.9 mA
|
XG 150-5.6 |
9.5 mV
|
2.6 mA
|
XG 300-2.8 |
17 mV
|
2.3 mA
|
XG 600-1.4 |
32 mV
|
2.1 mA
|
Load Regulation |
Model |
Voltage (0.005% of rated
output voltage + 2 mV)6
|
Current (0.02% of rated
output current +5 mA)7
|
XG 6-110 |
2.3 mV
|
27 mA
|
XG 8-100 |
2.4 mV
|
25 mA
|
XG 12-70 |
2.6 mV
|
19 mA
|
XG 20-42 |
3.0 mV
|
13.4 mA
|
XG 33-25 |
3.7 mV
|
10 mA
|
XG 40-21 |
4 mV
|
9.2 mA
|
XG 60-14 |
5 mV
|
7.8 mA
|
XG 80-10.5 |
6 mV
|
7.1 mA
|
XG 100-8.5 |
7 mV
|
6.7 mA
|
XG 150-5.6 |
9.5 mV
|
6.1 mA
|
XG 300-2.8 |
17 mV
|
5.6 mA
|
XG 600-1.4 |
32 mV
|
5.3 mA
|
Output Ratings |
Model |
Output Noise (rms, 300 kHz)
|
Output Ripple
(p-p, 20 MHz)
|
Voltage
|
Current
|
Voltage
|
XG 6-110 |
8 mV
|
200 mA
|
50 mV
|
XG 8-100 |
8 mV
|
180 mA
|
50 mV
|
XG 12-70 |
8 mV
|
120 mA
|
50 mV
|
XG 20-42 |
8 mV
|
75 mA
|
50 mV
|
XG 33-25 |
8 mV
|
60 mA
|
50 mV
|
XG 40-21 |
8 mV
|
45 mA
|
50 mV
|
XG 60-14 |
8 mV
|
35 mA
|
50 mV
|
XG 80-10.5 |
8 mV
|
25 mA
|
80 mV
|
XG 100-8.5 |
8 mV
|
20 mA
|
80 mV
|
XG 150-5.6 |
10 mV
|
16 mA
|
100 mV
|
XG 300-2.8 |
25 mV
|
10 mA
|
150 mV
|
XG 600-1.4 |
50 mV
|
6 mA
|
250 mV
|
1. Maximum output voltage is guaranteed to be 0.1% of the rated voltage at zero output setting, using the front panel or digital remote programming modes.
2. Maximum output current is guaranteed to be 0.2% of the rated current at zero output setting, using the front panel or digital remote programming modes, and when measured with rated load resistance.
3. Total output power is also based on AUX1 Output Voltage (5 V) and AUX1 Output Current (0.5 A) and AUX2 Output Voltage (15 V) and AUX2 Output Current (0.5 A).
4. From 85-132 Vac or 170-265 Vac, constant load.
5. From 85-132 Vac or 170-265 Vac, constant load.
6. From no load to full load, constant input voltage.
7. For load voltage change, equal to the unit voltage rating, constant input voltage.
8. For 6 V models the current ripple is measured at 2-6 V output voltage and full output current. For all other models, the current ripple is measured at 10-100% output voltage and full output current. |
Output Ratings |
Model |
Maximum Recommended Remote Sense Line Drop Compensation per Line 9
|
Up-prog. Response Time, 0~Vmax 10
|
Efficiency (100/200 VAC input) 11
|
XG 6-110 |
1 V
|
60 ms
|
75/77%
|
XG 8-100 |
1 V
|
60 ms
|
77/80%
|
XG 12-70 |
1 V
|
60 ms
|
79.5/82.5%
|
XG 20-42 |
1.5 V
|
60 ms
|
82/85%
|
XG 33-25 |
2 V
|
60 ms
|
83/86%
|
XG 40-21 |
2 V
|
60 ms
|
83/87%
|
XG 60-14 |
3 V
|
60 ms
|
83/87%
|
XG 80-10.5 |
5 V
|
100 ms
|
83/87%
|
XG 100-8.5 |
5 V
|
100 ms
|
83/87%
|
XG 150-5.6 |
5 V
|
100 ms
|
83/87%
|
XG 300-2.8 |
5 V
|
150 ms
|
83/87%
|
XG 600-1.4 |
5 V
|
250 ms
|
83/87%
|
Output Ratings |
Model |
Down-prog. Response Time: Full Load
|
Down-prog. Response Time: No Load
|
Over-Voltage Trip Point
|
XG 6-110 |
60 ms
|
300 ms
|
0.5-7.5 V
|
XG 8-100 |
60 ms
|
400 ms
|
0.5-10 V
|
XG 12-70 |
60 ms
|
500 ms
|
1-15 V
|
XG 20-42 |
60 ms
|
600 ms
|
1-24 V
|
XG 33-25 |
60 ms
|
700 ms
|
2-39 V
|
XG 40-21 |
60 ms
|
800 ms
|
2-44 V
|
XG 60-14 |
60 ms
|
900 ms
|
3-66 V
|
XG 80-10.5 |
100 ms
|
1000 ms
|
3-95 V
|
XG 100-8.5 |
100 ms
|
1200 ms
|
3-125 V
|
XG 150-5.6 |
100 ms
|
1800 ms
|
3-180 V
|
XG 300-2.8 |
150 ms
|
2200 ms
|
5-330 V
|
XG 600-1.4 |
250 ms
|
3500 ms
|
5-660 V
|
Output Performance Specifications |
Temperature Coefficient |
100 PPM/° C from rated output voltage, after a 30-minute warm-up* |
Drift (8 hours) |
0.05% of rated output voltage & current over an 8 hour interval with constant line, load & temperature, after a 30-minute warm-up |
Hold-up Time |
Typical 20 ms at any rated input line. |
Transient Response Time 13 |
Less than 1 ms for 6 V to 60 V models. Less than 2 ms for 80 V to 600 V models* |
Meter Accuracy |
0.5% ± 1 count |
Isolation 12 |
1500Vac or 2121Vdc between mains terminals and accessible conductive parts / chassis ground.
Output to chassis 500Vac. |
Environmental Specifications (Indoor Use) |
Operating Temperature Range |
32°F to 122°F, 100% load (0°C to 50°C) |
Storage Temperature Range |
-4°F to 158°F (-20° C to 70°C) |
Operating Humidity Range |
30-90% RH (no condensation) |
Storage Humidity Range |
10-95% RH (no condensation) |
Operating Altitude |
Up to 6,500 feet (2,000 m) |
Installation Category |
II (IEC 1010-1) |
Pollution Degree |
2 (IEC 1010-1) |
Regulatory Approvals |
Safety |
CSA 22.2 No. 61010-1, 60950-1-07 and UL61010-1, UL60950-1-(2nd Ed) 12. Marked with cCSAus, CE for EMC & low voltage directive |
EMC |
Complies with EN61326-1
Complies with EN55022, Class B, FCC Part 15B for conducted emissions
Complies with EN55022, Class A, FCC Part 15A for radiated emissions
Complies with EN61000-4 series of standards for immunity |
9. When using remote sense, the total of the load voltage and the load line drops must not exceed the rated output of the power supply. For example, for an XG 6-110 in an application with 1 V of load line loss (0.5 V/Line), the maximum available load voltage would be 6-1= 5 V. Note: The unit may operate at higher output voltages than this, but there is no guarantee that the power supply will meet performance specifications. Ultimately, the upper limit of the output voltage will be determined by internal circuitry of the power supply (non-adjustable.)
10. With rated, resistive load.
11. At maximum output power.
12. Double insulation on primary to secondary isolation barriers. Basic insulation primary to protective earth ground.
13. Time for the output voltage to recover within 0.5% at its rated output for a load change 10-90% of rated output current. Output set point 10-100%. |