Input/output Impedance
|
50 ohms
|
RF Input/ Sample Connectors
|
Type N Female, unless specified otherwise
|
RF Output Connector
|
Type 716 Female up to 7.5 GHz, 4 - 8 GHz is WRD350 8 - 12 GHz is WR90, 12 - 18 GHz is WR62, 7.5 - 18 GHz is WRD750, 6.5 - 18 GHz is WRD650 Other waveguides available by request or specification (see Option 117)
|
Input VSWR
|
2.0:1
|
Output VSWR
|
2.5:1
|
Pulse Input
|
BNC Female Front Panel {TTL into 50 ohms standard} consult factory for special requirements
|
Pulse Width Range
|
Up to CW
|
PRF Range
|
Up to 100 kHz Standard, Higher PRF ranges available consult factory
|
Duty Cycle
|
Up to CW (Higher PRF ranges subject to TWT specification)
|
Rise & Fall Time
|
25 nsec nominal; 40 nsec maximum
|
Pulse to Pulse Jitter
|
±5 nsec maximum
|
Pulse Width Jitter (Distortion)
|
±5 nsec maximum
|
Pulse Recovery Time
|
150 nsec maximum
|
Pulse Delay
|
250 nsec maximum / 180 nsec typical
|
Pulse Droop
|
0.5 dB/100 usecs, 0.1 dB/10 usec
|
Power Output Stability
|
0.2 dB Pulse to Pulse at constant drive level & PRF
|
Pulse On/Off Ratio
|
80 dB
|
Phase Stability Pulse to Pulse
|
±1 degree nominal
|
Operating Temp
|
0º to 50º C
|
Non-operating Temp
|
-40º to 70º C
|
Humidity
|
95% without condensation
|
Altitude
|
10,000 feet operating, 50,000 non-operating
|
Cooling System
|
Air cooled, self contained
|
Modulation
|
All types, AM, FM, Pulse
|
Configuration
|
Rack Mount as specified in Model Table
|
Spurious Outputs
|
<-60 dBc nominal
|
Standard Prime Powers
|
100, 115, 120 VAC ±10% 50/60 Hz, single phase 200, 220, 230, 240 VAC ±10% 50/60 Hz, single phase 100/200VAC,115/208 or 200/220/230/240 VAC ±10% 50/60 Hz, three phase Wye or Delta and/or 400 Hz power is available.
|
Special Prime Powers other then listed are subject to availability
|