RF Data |
Frequency range |
9 kHz to 225 MHz instantaneously |
Nominal output load |
50 Ω |
Nominal power |
3000 W (64.8 dBm), 5000 W (67 dBm),10 000 W (70 dBm) |
Modulation capability |
AM, FM, φM, PM |
Nominal power gain |
3000 W model |
68.2 dB |
5000 W model |
70.4 dB |
10000 W model |
73.4 dB |
Gain flatness |
±3.0 dB |
Gain adjustment range |
> 15 dB |
Harmonics |
3000 W model
9 kHz to 110 MHz at 3000 W
110 MHz to 225 MHz at 2800 W |
< -20 dBc |
5000 W model
9 kHz to 110 MHz at 5000 W
110 MHz to 225 MHz at 3500 W |
< -20 dBc |
10 000 W model
9 kHz to 110 MHz at 10 000 W
110 MHz to 225 MHz at 8000 W |
< -20 dBc |
Spurious |
carrier offset > 100 kHz, starting at 1 MHz |
-80 dBc (nom.), max. -70 dBc |
Noise figure at maximum gain |
5 kHz to 50 MHz |
< 16.0 dB (nom.) |
50 MHz to 225 MHz |
< 9.0 dB (nom.) |
Nominal input impedance |
50 Ω |
Input level for nominal output power |
-3.4 dBm |
Input VSWR into 50 Ω |
max. 2:1 |
Maximum input level |
RF |
+5 dBm |
DC |
0 V |
Nominal output impedance |
50 Ω |
Nominal forward output power |
at VSWR < 6:1 |
continuous, without foldback |
at VSWR > 6:1 |
continuous, with gradual foldback to approx. 50 % of output power depending on load impedance |
Output mismatch protection, VSWR |
100 %, without damage |
RF sample and detected RF sample signals |
RF sample signal coupling factor |
RF forward and reflected sample ports, optional |
approx. 70 dB (see test report for details) |
Detected sample signal level |
Detected forward and reflected sample ports, optional |
to 3.0 V DC (see test report for details) |
Mechanical specifications of amplifier system |
Dimensions (rack setup, W × H × D, incl. handles, stands and crane lugs) |
3000 W model |
600 mm × 1570 mm × 1100 mm
(23.62 in × 61.81 in × 43.31 in) |
5000 W model |
600 mm × 2050 mm × 1100 mm
(23.62 in × 80.71 in × 43.31 in) |
10000 W model |
1200 mm × 2050 mm × 1100 mm
(47.24 in × 80.71 in × 43.31 in) |
Mechanical specifications of heat exchanger |
Dimensions (W × H × D, incl. handles and stands) |
3000 W model |
1241 mm × 558 mm × 400 mm
(48.86 in × 21.97 in × 15.75 in) |
5000 W model |
1125 mm × 925 mm × 600 mm
(44.29 in × 36.42 in × 23.62 in) |
10000 W model |
2400 mm × 1150 mm × 600 mm
(94.49 in × 45.27 in × 23.62 in) |
Connectors |
Connecting plate at rack top cover or at bottom of rear panel |
RF input port |
N female |
Sample ports, for RF or detected RF |
N female |
Ethernet |
RJ-45 |
Interlock |
WAGO X-COM®, 7€‘pin, female |
Amplifier state |
WAGO X-COM®, 7€‘pin, female |
Transparent I/O, optional |
2 × WAGO X-COM®, 7€‘pin, female |
Rear panel, bottom |
RF output port |
1 5/8"" EIA female |
Mains power |
3000 W model |
5 × 4 mm2 power cord |
5000 W model |
5 × 10 mm2 power cord |
10000 W model |
5 × 16 mm2 power cord |
Coolant supply |
rack top cover, rear panel or rack shelf |
Electrical specifications of amplifier system |
Nominal operating voltage ranges |
3000 W model,
5000 W model,
10 000 W model |
380 V to 415 V AC ± 10 %, three-phase with N,
50 Hz to 60 Hz ± 6 % |
3000 W model,
5000 W model |
208 V to 240 V AC ± 10 %, three-phase,
50 Hz to 60 Hz ± 6 % |
Nominal current |
3000 W model, at 230 V, per phase |
< 20.5 A |
5000 W model, at 230 V, per phase |
< 35 A |
10 000 W model, at 230 V, per phase |
< 72 A |
Nominal power |
3000 W model, RFcw = 3000 W (RMS), VSWR = 1 |
< 14.2 kVA |
5000 W model, RFcw = 5000 W (RMS), VSWR = 1 |
< 24 kVA |
10 000 W model, RFcw = 10 000 W (RMS), VSWR = 1 |
< 50 kVA |
Electrical specifications of heat exchanger |
Nominal operating voltage range |
230 V AC ± 10 %, single-phase, 50 Hz to 60 Hz ± 6 % |
Current at 230 V |
3000 W model |
< 1.5 A |
5000 W model |
< 3.5 A |
10000 W model |
< 13 A |
Power consumption |
3000 W model |
< 350 VA |
5000 W model |
< 810 VA |
10000 W model |
< 3000 VA |
Cooling specifications |
Cooling circuit |
closed cooling system, automatic pressure balancing |
Coolant |
39 % v/v Antifrogen® N
(based on monoethylene glycol, water and anticorrosion additives) |
Heat exchanger |
Capacity |
3000 W model |
max. 9.5 kW |
5000 W model |
max. 15.7 kW |
10000 W model |
max. 41 kW |
Air volume flow |
3000 W model |
6200 m3/h |
5000 W model |
5145 m3/h |
10000 W model |
20100 m3/h |
Mounting type |
indoor or outdoor, floor installation |
Cooling hose |
Outside diameter |
3000 W model, 5000 W model |
2 × 40 mm (2 × 1.57 in) |
10 000 W model |
2 × 51 mm (2 × 2.0 in) |
Bending radius |
280 mm (11 in) |
Graphical user interface |
Local display |
200 × 48 pixels, monochrome |
Web GUI via Ethernet |
RJ-45, 10/100 Mbit/s, autonegotiation, half/full duplex |