Frequency Range
|
25 to 3300 MHz
|
Frequency Accuracy
|
(RF Source Mode) 75 parts per million @ 25°C*
|
Frequency Resolution
|
100 kHz
|
SWR:
|
Range
|
1.00 to 65.00
|
|
Resolution
|
0.01
|
Return Loss
|
Range
|
0.00 to 54.00 dB
|
|
Resolution
|
0.01 db
|
Test Port, Type N 50 Ohms ***Immunity to Interfering signals up to the level of –5 dBm, reflection
|
Maximum Input (Damage Level)
|
Test Port, Type N: +22 dBm
|
RF Detector:
|
+20 dBm
|
Measurement Accuracy
|
Measurement accuracy depends on calibration components
|
Precision calibration components have a directivity of 42 dB
|
Cable Insertion Loss
|
Range
|
0.00 to 54.00 dB
|
Resolution
|
0.01 dB
|
Frequency Reference
|
Aging
|
±1 ppm/yr
|
Accuracy
|
±2 ppm
|
Internal Memory:
|
Trace Memory
|
40 maximum
|
Instrument configuration
|
10 setup locations
|
RS-232: 9 pin D-sub, three wire serial
|
Electromagnetic Compatibility Meets European community requirements for CE marking
|
Power Supply
|
External DC Input: +11 to +15 Vdc, 1250 mA max
|
Temperature
|
Storage: –20° C to 75° C
|
Operation: 0° C to 50° C
|
Weight
|
4 lbs (1.82 kg)
|