Model Number / Type
|
Tx Frequency (MHz)
|
Rx Frequency (MHz)
|
Master Control Unit (controls up to 4 RF Units)
|
All
|
All
|
RF Units
|
TETRA 400
|
390 ~ 400
|
380 ~ 384
|
E-TETRA400
|
420 ~ 430
|
410 ~ 412
|
AMPS/CDMA
|
869 ~ 896
|
824 ~ 851
|
EGSM900
|
925 ~ 960
|
880 ~ 915
|
GSM900
|
935 ~ 960
|
890 ~ 915
|
LTE-JP1500
|
1488 ~ 1520
|
1456 ~ 1480
|
DCS/GSM1800
|
1805 ~ 1880
|
1710 ~ 1785
|
PCS1900
|
1930 ~ 1990
|
1850 ~ 1910
|
AWS
|
2010 ~ 2155
|
1710 ~ 1755
|
TD-SCDMA(2000)
|
2010 ~ 2025
|
1900 ~ 1920
|
UMTS/W-CDMA
|
2110 ~ 2170
|
1920 ~ 1980
|
W-CDMA-JP
|
2150 ~ 2170
|
2110 ~ 2140
|
IMT-E(2600)
|
2620 ~ 2690
|
2500 ~ 2570
|
WiBro-KR
|
2110 ~ 2170 2300 ~ 2390
|
1910 ~ 1990
|
Accessories
|
Opt. 2
|
Accessory Kit: (2) low PIM cables 3m / 10ft, (1) low PIM cable 1m / 3ft, low PIM load 100W, adapters, torque wrench with hard carry case
|
Opt. 3
|
Low PIM Load 100W, < 165 dBc @ 2* 43W, DIN 7/16 (f)
|
Opt. 4
|
PIM Source: Generator with preset PIM value. Quick indication of system functionality. Ideal for test and training.
|
Transmitter
|
Carrier Power
|
+20 to +44 dBm (46 dBm optional)
|
Power Accuracy
|
+/- 0.35 dB
|
Frequency Accuracy
|
200 ppm
|
Reverse Pwr. Protection
|
+43 dBm for 5 sec
|
Receiver
|
Reverse IM @ 2x43dBmForward IM @ 2x43dBm
|
-129 dBm / -172 dBc typ.-125 dBm / -168 dBc typ.
|
Noise Floor
|
-140 dBm (300 Hz BW)
|
DynamicRange(typical)
|
> 96 dB (ref: -70 dBm)
|
Reverse Power Protection
|
+43 dBm for 5 sec
|
Operational Input Power
|
-40 dBm RMS
|
Max Input Power
|
-10 dBm
|
Measurement Accuracy
|
+/- 0.2 dB @ 2 x 43 dBm
|
Dimensions / Weight / Environment / Electrical
|
Dimensions Control Unit RF Units (exc. E-GSM) RF Units E-GSM
|
483 x 305 x 500 (mm) 483 x 667 x 143 (mm) 483 x 756 x 143 (mm)
|
Weight Control Unit RF Units
|
11.7 kg 25 – 28 kg
|
Temperature
|
-10 °C to +40 °C
|
Humidity
|
80%, RH (non condensing)
|
Protection
|
IP20
|
AC Power
|
100 to 240V 50/60 Hz
|
Power Consumption Control Unit RF Units
|
88 Watts (VA) 700 Watts (VA) max
|