Com-Power PS-400 Near Field Probe Set 9 kHz - 5 GHz
Com-Power PS-400 Near Field Probe Set 9 kHz - 5 GHz is designed to assist in troubleshooting EMI problems both at the board level and at the component level. It is used to detect radiation from cables, cases, traces and ICs. The broadband probe is used to locate the general area of emission. The tip probe is used to isolate the source to a specific trace or pin. Further analysis can be done using the contact tip probe (available with PS-500 probe set) by making direct contact with the circuit and then following the noisy trace to find the cause of emissions such as a broken transmission line or impedance mismatch.