RTCA DO-160 Section 16: Power Input - Environmental Conditions and Test Procedures for Airborne Equipment
The purpose of this standard is to define test conditions and procedures for AC and DC electrical power applied to the terminals of the equipment under test. It covers the following electrical power supplies:
- 14 V dc, 28 V dc and 270 V dc
- 115 Vrms ac and 230 Vrms ac at either a nominal 400 Hz frequency or over a variable frequency range which includes 400 Hz.