| Electrical Specifications |
| Detection |
Isotropic (X, Y and Z Axis Readings) |
| Frequency Range |
10 kHz - 1 GHz |
| Frequency Response with Correction |
10 kHz to 1 GHz ± 0.9 dB |
| Frequency Response |
10 kHz to 30 kHz - 2.5/+0.5 dB
30 kHz - 1 GHz +/- 1.0 dB |
| Dynamic Range |
2.0 to 800 V/m (Single Range) |
| Sensor Protection Caps Height |
43 mm |
| Resolution |
0.01 V/m |
| Isotropic Deviation |
± 0.5 dB @ 400 MHz dB |
| Linearity |
± 0.5 dB @ 27 MHz |
| Sample Rate (Typical) |
> 70 Samples second max. |
| Overload Withstand |
>1500 V/m CW |
| Physical Specifications |
| Physical Interface |
Duplex Optical Fiber (62.5 micron multimode)
FC Connectors for Laser cable, integral 1m optical cable
ST Connector for Transmitter cable, Integral 1m optical cable |
| Power |
Laser-powered |
| Operating Temperature Range |
10 to 40° C |
| Dimensions |
32 mm x 32 mm x 32 mm Housing
(1.25 in. x 1.25 in. x 1.25 in.)
36 mm (1.42 in) Sensor Protection Caps |
| Weight |
80 g ( 2.82 ounces ) |
| Mounting |
1/4"" - 20 UNC Internal Thread |