Insulation resistance measurement
|
Test voltage (dc)
|
Range (dc)
|
Accuracy (± reading)
|
250 V
|
< 200 kΩ 200 kΩ to 5 GΩ 5 GΩ to 50 GΩ > 50 GΩ
|
unspecified 5 % 20 % unspecified
|
500 V
|
200 kΩ 200 kΩ to 10 GΩ 10 GΩ to 100 GΩ > 100 GΩ
|
unspecified 5 % 20 % unspecified
|
1000 V
|
< 200 kΩ 200 kΩ to 20 GΩ 20 GΩ to 200 GΩ > 200 GΩ
|
unspecified 5 % 20 % unspecified
|
2500 V
|
< 200 kΩ 200 kΩ to 50 GΩ 50 GΩ to 500 GΩ > 500 GΩ
|
unspecified 5 % 20 % unspecified
|
5000 V
|
< 200 kΩ 200 kΩ to 100 GΩ 100 GΩ to 1 TΩ > 1 TΩ
|
unspecified 5 % 20 % unspecified
|
10000 V (1555 only)
|
< 200 kΩ 200 kΩ to 200 GΩ 10 GΩ to 2 TΩ > 2 TΩ
|
unspecified 5 % 20 % unspecified
|
Bar graph range
|
0 to 1 TΩ
|
Insulation test voltage accuracy
|
-0 %, +10 % at 1 mA load current
|
Induced ac mains current rejection
|
2 mA maximum
|
Charging rate for capacitive load
|
5 seconds per μF
|
Discharge rate for capacitive load
|
1.5 s/μF
|
Leakage current measurement
|
Range: 1 nA to 2 mA
|
Accuracy: ± (5 % + 2 nA)
|
Capacitance measurement
|
Range: 0.01 uF to 15.00 μF
|
Accuracy: ± (15 % rdg + 0.03 μF)
|
Timer
|
Range: 0 to 99 minutes
|
Resolution Accuracy: Setting: 1 minute Indication: 1 second
|
Live circuit warning
|
Warning Range: 30 V to 660 V ac/dc, 50/60 Hz
|
Voltage Accuracy: ± (15 % + 2 V)
|
General specifications
|
Display
|
75 mm x 105 mm
|
Power
|
12 V lead-acid rechargeable battery, Yuasa NP2.8-12
|
Charger Input (AC)
|
Charger Input (AC) 85 V to 250 V ac 50/60 HZ 20 VA
|
This Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal (ground pin) is not connected internally. The extra pin is for added plug retention only.
|
Dimensions
|
170 mm x 242 mm x 330 mm (6.7 in x 9.5 in x 13 in)
|
Weight
|
3.6 kg (7.94 lb)
|
Temperature (operating)
|
-20 ºC to 50 ºC (-4 ºF to 122 ºF)
|
Temperature (storage)
|
-20 ºC to 65 ºC (-4 ºF to 149 ºF)
|
Humidity
|
80 % to 31 ºC decreasing linearly to 50 % at 50 ºC
|
Altitude
|
2000 m
|
Enclosure sealing
|
IP40
|
Input overload protection
|
1000 V ac
|
Electromagnetic compatibility
|
EN 61326
|