Insulation Range
|
100 kΩ to 20 GΩ (also 0 Ω and ∞ )
|
Test Voltages (DC)
|
500 V, 1000 V, 2500 V & 5000 V
|
Test Voltage Accuracy
|
±5% of nominal test voltages on 20 MΩ load
|
Test Voltage Stability
|
<±1% (180 rpm to 240 rpm
|
Insulation Accuracy (at 0 - 30°C) (32 to 86°F)
|
±2,5% of full scale deflection
|
Short Circuit Current
|
1,5 mA ± 0,5 mA
|
Maximum capacitance of load
|
5 μF
|
Interference Rejection
|
1 mA rms at 50 to 60 Hz
|
Discharge Resistor
|
<500 kΩ
|
Voltage RANGE
|
0 to 600 V a.c.
|
Indication of DC Accuracy
|
± 2,5% f.s.d. AC (with rotary switch in the V position)
|
General Overload rating
|
720 Vac or DC
|
Scale Length
|
2,8 in. (72 mm) (96°)
|
Power Supply
|
Low voltage brushless Generator and 8 x AA cells (LR6)
|
Battery Life
|
Typically 2000 five second tests at 5 kV on 100 MΩ load
|
Battery Indicator
|
Loaded battery test
|