Cable Types
Standard Link Interface Adapters
|
Shielded and unshielded Twisted Pair (STP, FTP, SSTP and UTP) LAN cabling:
TIA Category 3, 4, 5, 5E and 6: 100Ω
ISO/IEC Class C and D: 100Ω and 120Ω
ISO/ IEC Class E, 100W ISO/ IEC Class F, 100Ω
Cat 6/ Class E permanent link adapters Plug type and life: shielded and unshielded cable, TIA Cat 3, 4, 5, 5e, and 6 and ISO/IEC Class C, D and E permanent link
Cat 6/Class E channel adapters Plug type and life: shielded and unshielded cable, TIA Cat 3, 4, 5, 5e, and 6 and ISO/IEC Class C, D and E channels
|
Test Standards
|
TIA Category 3 and 5e per TIA/EIA-568B
TIA Category 5 (1000BASE-T) per TIA TSB-95
TIA Category 6 per TIA/EIA-568B.2-1 (Addendum #1 to TIA/EIA-568B.2)
ISO/IEC 11801 Class C, D, and E
ISO/IEC 11801 Class F (DTX-1800 only)
EN 50173 Class C, D, E
EN 50173 Class F (DTX-1800 only)
ANSI TP-PMD
IEEE 802.3 10BASE-T, 100BASE-TX, 1000BASE-T
IEEE 802.5 (STP cabling, IBM Type 1, 150Ω ) Token Ring, 4 Mbps and 16 Mbps
|
Speed of Autotest
|
Full 2-way Autotest of Category 6 Twisted-Pair links in 12 seconds or less Full 2-way Autotest of ISO/IEC Class F links in 32 seconds
|
Supported Tests Parameters
|
(The selected test standard determines the test parameters and the frequency range of the tests)
Wire Map Length Propagation Delay Delay Skew DC Loop Resistance Insertion Loss (Attenuation) Return Loss (RL), RL @ Remote NEXT, NEXT @ Remote Attenuation-to-crosstalk Ratio (ACR), ACR @ Remote ELFEXT, ELFEXT @ Remote Power Sum ELFEXT, PSELFEXT @ Remote Power Sum NEXT, PSNEXT @ Remote Power Sum ACR, PSACR @ Remote
|
Display
|
3.7 in (9.4 cm) diagonal, 240 dots wide by 320 dots high, passive color, transmissive LCD with backlight.
|
Input Protection
|
Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage.
|
Case
|
High impact plastic with shock absorbing over-mold
|
Dimensions
|
Main unit and Smart Remote: 8.5 in x 4.4 in x 2.4 in (21.6 cm x 11.2 cm x 6cm), nominal
|
Weight
|
2.4 lb (1.1 kg), nominal (without adapter or module)
|
Operating Temperature
|
32°F to 104°F (0°C to 40°C)
|
Storage Temperature
|
-4°F to +140°F (-20°C to +60°C)
|
Operating relative humidity (% RH without condensation)
|
32°F to 95 °F (0°C to 35°C): 0 % to 90 % 95°F to 113°F (35°C to 45°C): 0 % to 70 %
|
Vibration
|
Random, 2 g, 5 Hz -500 Hz
|
Shock
|
1 m drop test with and without module and adapter attached
|
Safety
|
CSA C22.2 No. 1010.1: 1992 EN 61010-1 1st Edition + Amendments 1, 2
|
Pollution degree
|
Pollution Degree 2 as defined in IEC 60664 and applied to IEC 60950 ""Safety of Information Technology Equipment, 1999""
|
Altitude
|
Operating: 4000 m; Storage: 12000 m
|
EMC
|
EN 61326-1
|
Power
|
Main unit and remote: Lithium-ion battery pack, 7.4 V, 4000 mAh
Typical battery life: 12 to 14 hours
Charge time (with tester off): 4 hours (below 40 °C)
AC adapter/charger, USA version: Linear power supply; Input 108 V ac to 132 V ac, 60 Hz ; Output 15 V dc, 1.2 A
AC adapter/charger, international version: Switching power supply; Input 90 V ac to 264 V ac, 48 to 62 Hz; Output 15 V dc, 1.2 A (isolated output)
Memory backup power in main unit: Lithium battery
Typical life of lithium battery: 5 years The battery will not charge at temperatures outside of 0°C to 45°C (32°F to 113°F). The battery charges at a reduced rate between 40°C and 45°C (104°F and 113°F).
|
Calibration
|
Service center calibration period is 1 year
|
Performance Specifications
|
Note: all specifications for tests on twisted-pair cabling apply to 100 Ω cable. Contact Fluke Networks for information on measurement performance for cable with a different impedance.
|
Baseline accuracy
|
The baseline accuracy of all DTX Series testers meets or exceeds the requirements of Level IV as in draft 2nd Edition of IEC 61935-1 over the frequency range supported by the tester.
|
Category 6/Class E link test modes (and lower link categories)
|
DTX Cable Analyzer far exceeds Level III requirements of TIA/EIA-568-B.2-2 and IEC 61935-1
|
Class F link test modes
|
DTX-1800 is compliant with Level IV requirements as in the draft 2nd edition of IEC 61935-1.
|
Length for Twisted Pair Cabling
|
(Length specs do not include the uncertainty of the cable's NVP Value)
|
Parameter
|
Single-ended Test Dual-ended Test (Main and Remote)
|
Range
|
800 m (2600 ft) - Single-ended Test 150 m (490 ft) - Dual-ended Test (Main and Remote)
|
Resolution
|
0.1 m or 1 ft - Single-ended Test 0.1 m or 1 ft - Dual-ended Test (Main and Remote)
|
Accuracy
|
± (1m + 4%) - Single-ended Test ± (1m + 4%) - Dual-ended Test (Main and Remote)
|
Delay Skew
|
|
Parameter
|
Twisted Pair Cabling
|
Range
|
0 ns to 100 ns
|
Resolution
|
1ns
|
Accuracy
|
± 10 ns
|
DC Loop Resistance Test
|
|
Parameter
|
Twisted Pair Cabling
|
Range
|
O Ω to 53Ω
|
Resolution
|
0.1 Ω
|
Accuracy
|
± (1 Ω + 1%)
|
Overload Recovery Time
|
Less than 10 minutes to rated accuracy following over-voltage. Referencing is required after repeated or prolonged over-voltage.
|