| General Specifications | 
| Weight, with battery | 0.86 kg (1.9 lb) | 
| Dimensions | 19.1 x 15.2 x 4.4 cm (7.5 x 6.0 x 1.75 in) | 
| Display | LCD touch screen, 640 x 480 pixels, TFT (active) color panel, touch pad | 
| LED indicators | 6 (including power LED) | 
| Carrying Case | Rugged carrying case for mainframe and standard accessories | 
|  |  | 
| Power | 
| Battery | Lithium Ion 7.2V DC (nominal), 4.2Ah, removable/rechargeable | 
| Battery life | 4 hour typical, 10 hour in standby mode | 
| External AC adapter/battery charger | AC input: 90 to 264 V ac, 48 to 62 Hz; 1.5 A | 
|   | DC output: 15 V dc, 1.2 A (isolated output) | 
| Auto Charger | 12V “cigarette lighter” charger with 6 foot (1.8 m) fully extended coiled cord and LED power indication | 
|  |  | 
| Ports | 
| Communication and accessory ports | 1 USB (supports out-of-band NIC for remote control), 1 PCMCIA/Cardbus (PC Card type II), 1 SFP cage, 1 CompactFlash (Card Type I/II), 1 DB-9 serial, headphone jack, microphone jack, Kensington lock receptacle | 
| RJ-45 / Copper Port | RJ-45 10/100/1000BASE-T Ethernet.LAN option must be enabled to activate the copper port.
 | 
| Fiber Port | Small Form-factor Pluggable (SFP) in accordance with MSA.Fiber option must be enabled to activate the fiber port.
 | 
| Supported SFP Modules | 1000BASE- LX, SX, ZX, BX, 100BASEFX.Transceiver models MS-SX, MS-LX, and MS-100FX require EtherScope software version 4.0 or higher.
 | 
| SFP Connector | Duplex LC | 
|  |  | 
| Environmental and safety | 
| Operating Temperature | 0° to +50°C (32° to 122°F) with up to 95% relative humidity | 
| Battery Charging | 10° to +40°C (50° to 104°F) with up to 95% relative humidity | 
| Temperature |   | 
| Storage temperature | -20° to +60°C (-4° to 140°F) | 
| Shock and vibration | Meets requirements of MIL-PRF-28800F for Class 3 equipment | 
| Safety | CSA Canada and United States, CE, FCC Part 15 Class A, C-TICK N10140; UL and CSA approvals for universal AC adapter.EMC Complies with EN61326, Class A, Criteria C
 | 
|  |  | 
| Copper media | 
| Cable types | Unshielded twisted pair LAN cables (100 and 120 Ohm UTP) | 
|   | Foil-screened twisted pair LAN cables (100 and 120 Ohm ScTP) | 
| Cable length | 1 to 305 m (3 to 1000 ft), accuracy dependent upon the cable type selected | 
| Length resolution | ± [5% of reading + 1 m (3 ft)], with open, shorted, with wire map adapter, or terminated with reflection = 20% | 
| Receive level | 100 to 5000 mVp-p | 
| Datalink signal | 500 to 4000 mVp-p | 
| Measuring terminated cables | The Cable Verification feature tests the individual twisted-pairs of a cable that are terminated into most equipment vendor's Ethernet ports such as on a hub, switch or NIC. All cable tests other than WireView wire map and office locator ID are operational in the presence of datalink signal. | 
| Wiremapper/office locator compatibility | Detects combinations of shorts, opens, and connector miswires. Compatible with Fluke Networks WireView wire map adapter/office locator. | 
| Fault tolerance | The RJ-45 Ethernet connection on the analyzer is designed to withstand a maximum of 100 volts. | 
|  |  | 
| Fiber optic power measurements | 
| Receive Input Power, Transmit Output Power, Temperature, Voltage, TX Bias Current | Real time access to digital diagnostic monitoring of SFP operating parameters in accordance with the SFP Multi Source Agreement (MSA) and SFF-8472. | 
|  |  | 
| ProVision™ Tests | 
| Compatible remote devices | EtherScope, MetroScope, LinkRunner PRO/Duo with reflector, layer 1 loopback, 802.3ah deviceNote: An EtherScope with v5 software or a LinkRunner Duo is required for 16K jumbo frame testing.
 | 
| Test Configuration | Each test may be made up of an unlimited number of suites which run sequentially. Each suite may measure a maximum of eight streams total (including upstream and downstream) from one to four peer devices or a maximum of four streams (roundtrip) from one to four reflectors. | 
| Test Duration | Each suite can run for any length of time from 1s to 24h. Suites may be run sequentially for virtually unlimited test lengths. | 
| Tests | Throughput, Latency, Jitter, Loss/BERT, measured in parallel | 
| Application port | User defined, per stream | 
| Frame content | All 0s, all 1s, alternating 1s and 0s, Pseudo Random Bit Sequence (PRBS), Incrementing Byte, HFPAT, LFPAT, MFPAT, LCRPAT, SCRPAT | 
| Frame size | 48, 64, 128, 256, 512, 1024, 1280, 1518, 2024, 9000, RFC-2544 sweep, Jumbo sweep, or user-defined including jumbo sizes up to 16000 | 
| Rate (bps) | Up to 1000 Mbps (selectable per stream) | 
| 802.1Q settings | VLAN Id, QoS with CoS and ToS , QinQ VLAN Id, priority for each individual stream or all streams. Programmable TPID, DEI, CFI and VID for all streams | 
| IP TOS settings | IP Precedence/TOS parameter, DiffServe Code Point | 
| Pass/Fail Limits | Throughput (separate upstream and downstream), Latency, Jitter, Loss/BERT | 
| Summary Display | Summary matrix of all streams and all measurements; IP/Mac addresses, VLANPriority/TOS, status,Tx and Rx rates in bps and fps, frames sent and lost, loss ratio, errored intervals; current, average, maximum latency and jitter. | 
| Detailed Display | Individual measurements may be shown in tabular (by frame size), graphical (by frame size) or trending (by current interfal or total test duration for all frame sizes). | 
| Frame Loss Statistics | Total, current, and maximum for: frames sent and lost, loss ratio, BER, errored intervals, severely errored intervals | 
| Data Export | Throughput, Frames Sent/Received, Loss, Delay and Jitter test results for each stream are time stamped and saved to the CD card once per measurement interval for the duration of the test. | 
|  |  | 
| RFC 2544 Performance Tests | 
| Compatible remote devices | EtherScope, MetroScope, LinkRunner PRO/Duo with reflector, layer 1 loopback, 802.3ah device | 
| RFC-2544 Compliant Tests | Throughput, Latency, Frame Loss, Back-to-Back | 
| Additional Performance Tests | Loss Rate, Jitter, FrameBERT | 
| Frame content | All 0s, all 1s, alternating 1s and 0s, Pseudo Random Bit Sequence (PRBS), Incrementing Byte, HFPAT, LFPAT, MFPAT, LCRPAT, SCRPAT | 
| Frame size | 64, 128, 256, 512, 1024, 1280, 1518, 9000, RFC-2544 sweep, Jumbo sweep, or user-defined including jumbo sizes up to 16000 | 
| Application port | User defined | 
| Rate (bps) | Up to 1000 M | 
| 802.1Q settings | VLAN Id, priority | 
|  |  | 
| IP TOS settings | IP Precedence/TOS parameter, DiffServe Code Point | 
| Throughput settings | Duration, maximum rate, measurement accuracy, pass/fail limits | 
| Latency settings | Duration, rate, iterations, pass/fail limits | 
| Frame loss settings | Duration, rate, step size, pass/fail limits | 
| Frame loss settings | Duration, rate, step size, pass fail | 
| Back to Back settings | Min and Max duration, rate, iterations, pass/fail limits | 
| Loss Rate | Duration, rate, pall/fail limits | 
| Jitter Settings | Duration, rate, pass/fail limits | 
| FrameBERT Settings | Duration, rate, pass/fail limits | 
|  |  | 
| Server Response Tool | 
| TCP Port Response | DNS Name, IP address, port name, port number, port responsiveness | 
| TCP Trace Route | Hop Count, router name, IP address, average RTT and percentage of total RTT | 
|  |  | 
| Internetwork Throughput Option | 
| Compatible remote device | EtherScope, MetroScope, LinkRunner PRO/Duo with reflector option, OptiView v3 Integrated Network Analyzer, OneTouch Series II | 
| Frame content | All 0s, all 1s, alternating 1s and 0s, Pseudo Random Bit Sequence (PRBS) | 
| Frame size | 64, 128, 256, 512, 1024, 1280, 1518, sweep of all sizes | 
| Rate (bps) | 12336 to 1000 M | 
| Duration(s) | 1 to 64,800 (18hr) | 
| Results | Frames sent, received, rate and percent loss for both upstream and downstream directions | 
| Results format | Tabular, graphical, xml-based report | 
|  |  | 
| Traffic generator | 
| Traffic type | Broadcast, multicast or unicast, FCS errors | 
| Frame type | Layer 1 FLUKE, Layer 2 FLUKE, Layer 3 FLUKE, Benign Ethernet, Benign LLC, NetBEUI, Benign IP, IP/ICMP Echo, IP/UDP Echo, IP/UDP Discard, IP/UDP Chargen, IP/UDP NFS, IP/UDP NetBIOS | 
| Frame size | 48, 64, 128, 256, 512, 1024, 1280, 1518, 9000, user defined up to 16000B | 
| Rate | Utilization (%): >0 – 100, Frames/second: 1 – 1488095 | 
| Duration | Seconds: 1 – continuous, Frames: 1 – continuous | 
|  |  | 
| Service Performance Tool | 
| Category of devices tested
 | DHCP Servers, DNS Servers, E-mail Servers (SMTP, POP3), FTP Servers, NT File Servers, Web Servers, WINS Servers, User-Defined Servers | 
| Test controls | Iterations, interval | 
| Add device by | IP address or host name (except Web Server where URL added) | 
| DHCP Server pass/fail criteria | Ping response time, server response time | 
| DHCP Server BOOTP parameters (optional) | Subnet mask, domain server, WINS server, NetBIOS scope, POP3 server, router/default gateway, client DNS domain, NetBIOS node type, SMTP server, web server | 
| DNS Server pass/fail criteria | Ping response time, server response time | 
| E-mail Server pass/fail criteria | Ping response time, SMTP SYN/ACK response time, SMTP response time, POP3 SYN/ACK response time, POP3 response time | 
| E-mail Server operation modes | Connect only, log in only, send/receive | 
| FTP Server pass/fail criteria | Ping response time, SYN/ACK response time, connect time, disconnect time, delete file time, write rate, read rate | 
| FTP Server operation modes | Server response, read, write/read/delete | 
| NT File Server pass/fail criteria | Ping response time, SYN/ACK response time, connect time, disconnect time, delete file time, write rate, read rate | 
| NT File Server operation modes | Server response, read, write/read/delete | 
| Web Servers pass/fail criteria | Web Server name lookup time, ping response time, SYN/ACK response time, first reply time, receive time, receive rate | 
| WINS Servers pass/fail criteria | Ping response time, server response time | 
| User-Defined Servers pass/fail criteria | Ping response time, SYN/ACK response time | 
| Results format | Tabular, graphical, xml-based report | 
|  |  | 
| 802.3ah Client | 
| Functions | Remote device discovery, loop-up with 1s keep-alive, loop down. May be run in background while other MS functions are active. | 
| Display | Loopback capability of remote, OAM status OAM mode link status, maximum OAM size, remote state | 
|  |  | 
| IPTV Tests | 
| Configuration | Multicast Group IP, Port Number, join, leave, RTSP URL, setup, play, pause, teardown | 
| Results | IGMP Latency, Total Packets Sent, Connected Time, Received Packet Rate, RFC-4445 MDI Delay Factor and Media Loss Rate for MPEG-2 streams | 
|  |  | 
| Instrument Settings | 
| TCP/IP | DHCP, static | 
| Management TCP/IP | DHCP, static (management using USB Ethernet adapter purchased separately) | 
| 802.1Q | LAN: S-VLAN, C-VLAN, TPID, Priority, DEI, VID | 
| IP Type Of Service (TOS) | LAN: IP precedence, DSCP | 
| Security | LAN: 802.1XWLAN: 802.1X, WEP, WPA PSK, 802.11i PSK, WPA, WPA2
 | 
| 802.1X EAP type | TLS, GTC, MD5, MSCHAPV5, PEAP GTC, PEAP MD5, PEAP MS-CHAP-V2, PEAP TLS, TTLS PAP, TTLS CHAP, TTLS MSCHAP, TTLS MSCHAP-V2, TTLS EAP-MD5, TTLS EAP-GTC, TTLS-EAP-MSCHAP-V2, TTLS EAP-TLS, EAP FAST | 
| Active tests | LAN: User defined tests to appear on detailed view home page and drop down navigation | 
| SNMP | LAN: v1, v2, v3 (with SHA and MD5 authentication, DES encryption) | 
| Ethernet | LAN: Auto-negotiation, force setting, MAC address | 
| Instrument security | Password control for remote UI, ProVision and RFC2544 tests, SNMP settings, and 802.1X | 
| General | Enable as remote, advanced remote NAT/Proxy settings, user preferences | 
| Group names | WLAN: assign alias to one or more devices | 
| Tools | 
| LAN | Ping, trace route, trace switch route, traffic generator, web browser, telnet, SSH telnet, terminal, FTP, TFTP, xDP port reporter (CDP, LLDP), Service Performance Tool, Remove CF Card, Lock Screen, Report | 
| WLAN | Ping, trace route, web browser, telnet, SSH telnet, terminal, FTP, TFTP, wireless throughput, report | 
| Wireless LAN Adapter Card | 
| Specification compliance | IEEE 802.11a, 11b, 11g | 
| Certifications | FCC part 15, Telec, CTICK, ETSI, EN301893, EN60950 | 
| Interoperability | WECA Compliant | 
| Interface | 32-bit Cardbus | 
| Outdoor operating range | Up to 515 m (1690 ft) | 
| Indoor operating range | Up to 85 m (279 ft) | 
| Data rate | 802.11a: up to 54 Mbps, 802.11b: up to 11 Mbps, 802.11g: up to 54 Mbps | 
| Output power | 18 dBm peak power | 
| Infrastructure mode | BSS | 
| External antenna connector jack | Hirose MS-147 | 
| Wireless LAN Directional Antenna | 
| Frequency range | 2.4 – 2.5 and 4.9 - 5.9 GHz | 
| Minimum gain | 5.0 dBi in the 2.4 GHz band and 7.0 dBi in the 5 GHz band | 
| External antenna connector plug | Hirose MS-147 |