SYSTEM
|
Measurement method
|
Reverse (reflected) PIM, 3rd order
|
Residual PIM
|
< -125dBm/-161dBc max (<-130dBm/-166dBc typ)
|
User interface ports
|
1x RF output (7-16 DIN female)
1x RS-232 (R180601 interface cable required)
|
Display
|
2x LED bar displays indicate PIM level, battery level, display mode and alarms
|
TRANSMITTER
|
Transmit frequencies
|
See model table
|
Frequency accuracy
|
± 100ppm typ
|
Power per tone (fixed)
|
2x 4W (+36dBm)
|
Power accuracy (per tone)
|
± 1dB (max)
|
RECEIVER
|
Receive frequency
|
See model table
|
Measurement noise floor
|
< -134dBm
|
Measurement range
|
-80dBm to -130dBm
|
ELECTRICAL
|
Battery
|
25.9 VDC, 2500mAH Li-ion battery pack (internal)
|
Battery life
|
>1hr with RF power continuously on
|
Battery charger
|
External charger, 29.4 VDC, 1.2 Amp
|
MECHANICAL
|
Analyzer dimensions
|
14 x 9 x 3.5in (350 x 230 x 90mm)
|
Case dimensions
|
22 x 14 x 9in (550 x 350 x 230mm)
|
Analyzer weight
|
11lbs (5kg)
|
Analyzer + case weight
|
25lbs (11kg)
|
ENVIRONMENTAL
|
Operating temperature range
|
0°C to +45°C (32°F to 113°F)
|
Storage temperature range
|
-10°C to +60°C (14°F to 140°F)
|
Ingress protection (IP)
|
IP54
|
Relative humidity
|
5% to 95% RH non-condensing
|