MIL-STD 461 CS109


DEPARTMENT OF DEFENSE INTERFACE STANDARD

MIL-STD 461 CS109 Conducted Susceptibility, Structure Current

This test procedure is used to verify the ability of the EUT to withstand structure currents.

Applicability

This requirement is applicable from 60 Hz to 100 kHz for equipment and subsystems that have an operating frequency of 100 kHz or less and an operating sensitivity of 1 μV or better (such as 0.5 μV). Handheld equipment is exempt from this requirement.

Limit

The EUT shall not exhibit any malfunction, degradation of performance, or deviation from specified indications, beyond the tolerances indicated in the individual equipment or subsystem specification, when subjected to the values shown on Figure CS109-1.

Test Equipment
  1. Signal generator
  2. Amplifier (if required)
  3. Isolation transformers
  4. Current probe
  5. Measurement receiver
  6. Resistor, 0.5 ohm
  7. Coupling transformer