Measurement Ranges
|
North American Version
|
Primary/Ambient Air Temperature
|
-4° to 999°F
|
Stack Temperature
|
-4° to 2192°F
|
Oxygen
|
0 to 20.9%
|
Carbon Monoxide (H2Compensated)
|
0 to 4,000 ppm
|
Carbon Monoxide, (High Range)
|
4,001 to 20,000 ppm
|
Nitric Oxide
|
0 to 3,000 ppm
|
Nitrogen Dioxide
|
0 to 500 ppm
|
Sulfur Dioxide
|
0 to 5,000 ppm
|
Pressure/Draft
|
-72 to +72 inwc
|
Calculated Ranges
|
Combustion Efficiency
|
0.1 to 100%
|
Excess Air
|
1.0 to 250%
|
Carbon Dioxide (Dry Basis)
|
0 to Fuel Dependent Maximum
|
NOx (NO + NO2)
|
0 to 3,500 ppm
|
NOx referenced to % O2
|
0 to 9,999 ppm
|
CO referenced to % O2
|
0 to 9,999 ppm
|
NO referenced to % O2
|
0 to 9,999 ppm
|
NO2 referenced to % O2
|
0 to 9,999 ppm
|
SO2 referenced to % O2
|
0 to 9,999 ppm
|
Accuracy
|
Oxygen
|
± 0.3% O2 (Flue Gas)
|
Stack or Flue Gas Temperature
|
± 4°F between 32 and 255°F (± 2°C between 0 and 124°C)
|
± 6°F between 256 and 480°F (± 3°C between 125 and 249°C)
|
± 8°F between 481 and 752°F (± 4°C between 250 and 400°C)
|
Primary-air/Ambient Temperature
|
± 2°F between 32 and 212°F (± 1°C between 0 and 100°C)
|
Pressure/Draft
|
± 2% Reading or 0.02 inwc -1 to 10 inwc
|
± 3% of Reading between ± -40 and ± 40 inwc
|
CO
|
± 5% of Reading or ± 10 ppm in the range of 0-2000 ppm CO
|
± 10% of Reading between 2001 to 4,000 ppm
|
NO
|
± 5% of Reading or ± 5 ppm whichever is greater between 0 to 2000 ppm NO
|
NO2
|
± 5% of Reading or ± 5 ppm whichever is greater between 0-500 ppm NO2
|
SO2
|
± 5% of Reading or ± 10 ppm whichever is greater between 0-2000 ppm SO2
|
Memory
|
500 Complete Combustion Test Records
|
Logged Memory
|
500 Complete Logged Combustion Test Records
|
Selectable Fuels
|
Natural Gas, Oil #2, Oil #4, Oil #6, Propane, Coal, Wood, Kerosene, Bagasse and Digester Gas
|
Size
|
9""H x 3""W x 2.5"" (22.9 cm x 7.6 cm x 6.3 cm)
|
Weight
|
1.4 lbs (0.6 kg)
|
Power Source
|
Four Disposable AA Alkaline Batteries. Optional Universal AC Adapter (100 to 240 Volts at 47 to 63 Hz)
|
Display
|
Full Color Graphic Display (320 x 240 pixels)
|
Warm Up Time
|
60 Second Total Warm Up Time (sensors are checked and autozeroed during warm up)
|