- Wide frequency range: 150 kHz - 30 MHz
- Coils matched to application
- Air core coils
- Individually calibrated
Com-Power LIN-115A Application
The LISN provides input power line impedance to the equipment under test (EUT) that is constant and independent of the line impedance of the external power source during conducted emissions testing.
In addition to providing constant power line impedance, the LISN functions as a low pass filter for the power to equipment under test. It prevents any radio frequency noise on the external power line from reaching the equipment under test (EUT).
Other functions of the LISN include; providing 50 Ohm connection to the spectrum analyzer to measure EMI voltage generated by the EUT and blocking measurement of EMI voltage emanated by other equipment connected to the external power source.
The insertion loss of the LISN may be significant at low frequencies. Therefore, at frequencies below 400 kHz, the insertion loss correction factor must be added back to the spectrum analyzer reading. The LISNs frequency vs insertion loss characteristic table for each line is shipped with each unit for this purpose. The impedance data shipped with each LISN is not used in measurement calculations. However, periodic calibration of the LISN impedance is necessary to ensure accurate conducted emissions measurements.