| SURGE TEST MODE |
| Coupling mode |
shielded and unshielded cable with up to 4 pairs |
| Test voltage |
Max. 3 kV* (1.2/50us)
(* only with connected RJ45 connector; if left open the max. test voltage is limited to 1.5 kV) |
| Residual voltage |
Max. 50V @3 kV Surge, line - PE |
| RINGWAVE TEST MODE |
| Coupling mode |
shielded and unshielded cable with up to 4 pairs |
| Test voltage |
Max. 4 kV* (0.5 us/100 kHz)
(* only with connected RJ45 connector; if left open the max. test voltage is limited to 1.5 kV) |
| Residual voltage
line - PE |
Max. 50V @2 kV Ringwave
Max. 50V @4 kV Ringwave |
| BURST TEST MODE |
| Coupling mode |
shielded cable with up to 4 pairs |
| Test voltage |
Max. 4 kV* (5/50 ns)
(* only with connected RJ45 connector; if left open the max. test voltage is limited to 1.5 kV) |
| Residual voltage
line - PE |
Max. 40 V @2 kV Burst
Max. 60 V @4 kV Burst |
| TELECOM LINE SPECIFICATIONS |
| Input/output |
RJ45 female connectors for telecom lines |
| Terminal layout |
Pair 1: pins 1/2
Pair 2: pins 3/6
Pair 3: pins 4/5
Pair 4: pins 7/8 |
| Data rate |
up to 1,000 MBit/s |
| Protection |
± 60 V between two pairs |
| Operating voltage |
max. 57 VDC |
| Operating current |
max. 1 A |
| INPUTS |
| Surge/Ringwave shield |
SHV connector |
| Surge unshielded |
SHV connector |
| Ringwave unshielded |
SHV connector |
| Burst |
SHV connector |
| GENERAL DATA |
| Dimensions (LxWxH) |
270 mm x 110 mm x 140 mm |
| Weight |
6.5 kg |
| Temperature |
5°C - 40°C (operation) |
| Rel. humidity |
10 % - 90 %, non-condensing |