ESD NX30 |
HV power supply |
Up to 30 kV DC |
Built-in Battery |
Approx. 30 k discharges; Battery is automatically recharged when connected to AC mains supply |
Interface |
Optical and interlock |
Self-calibration |
after power on, by user any time |
TEST LEVEL |
Contact discharge |
200 V - 30,000 V ± 5 % |
Air discharge |
200 V - 30,000 V ± 5 % |
Resolution |
100 V steps |
Holding time (AD) |
More than 5 s |
OUTPUT |
Contact Discharge Pulse |
per EN/IEC 61000-4-2 Ed.2, per ISO 10605 Ed.2 150 pF/330 ohm |
Rise time |
0.8 ns +/- 25%,
0.7 ns - 1 ns |
First peak current value |
7.5 A ± 15 % @2 kV
15 A ± 15 % @4 kV
22.5 A ± 15 % @6 kV
30 A ± 15 % @8 kV |
Current value at 30ns |
4.0 A ± 30 % @2 kV
8.0 A ± 30 % @4 kV
12.0 A ± 30 % @6 kV
16.0 A ± 30 % @8 kV |
Current value at 60ns |
2.0 A ± 30 % @2 kV
4.0 A ± 30 % @4 kV
6.0 A ± 30 % @6kV
8.0 A ± 30 % @8 kV |
GENERAL |
Weight Approx. |
6.5 kg (Base Station) |
Weight Approx. |
1,250 g (discharge gun) |
Supply voltage |
AC: 100 V - 240 V, 50/60 Hz |
Input Power |
130 VA max. |