TECHNICAL DETAILS |
CNI 503A, 5.5KV |
Three-phase CDN |
according to EN/IEC 61000-4-4 and EN/IEC 61000-4-5 for Burst up to 5.5kV Surge up to 5kV |
EUT supply |
3x480V, 16A AC |
Dimensions Size |
19"" / 6 HU |
Weight |
approx. 25kg |
CNI 503A.1, 5.5KV |
Three-phase CDN |
according to EN/IEC 61000-4-4 and EN/IEC 61000-4-5 for Burst up to 5.5kV Surge up to 5kV |
EUT supply |
3x690V, 16A AC |
Dimensions Size |
19"" / 6 HU |
Weight |
approx. 27kg |
CNI 503A1.1, 5.5KV |
Three-phase CDN |
according to EN/IEC 61000-4-4 and EN/IEC 61000-4-5 for Burst up to 5.5kV Surge up to 5kV |
EN 50121-x couplings |
manual selectable for 42 ohm, 0.5 uF, 12 ohm, 9 uF |
EUT supply |
3x480V, 16A AC |
Dimensions Size |
19"" / 6 HU, D 542 mm |
Weight |
22.75 kg |
CNI 503A2, 5.5KV |
Three-phase CDN |
according to EN/IEC 61000-4-4 and EN/IEC 61000-4-5 for Burst up to 5.5kV Surge up to 5kV |
EUT supply |
3x480V, 32A AC |
Dimensions Size |
19"" / 6 HU |
Weight |
approx. 35kg |
CNI 503A2.5, 5.5KV |
Three-phase CDN |
according to EN/IEC 61000-4-4 and EN/IEC 61000-4-5 for Burst up to 5.5kV Surge up to 5kV |
EN 50121-x couplings |
manual selectable for 42 ohm, 0.5 uF, 12 ohm, 9 uF |
EUT supply |
3x480V, 32A AC |
Dimensions Size |
19"" / 6 HU, D 542 mm |
Weight |
32.85 kg |
CNI 503A2.6, 5.5KV |
Three-phase CDN |
according to EN/IEC 61000-4-4 and EN/IEC 61000-4-5 for Burst up to 5.5kV Surge up to 5kV TEST ON function |
EUT supply |
3x480V, 32A AC
1,000V, 32A DC
500V, 150A DC |
Dimensions Size |
19"" / 34 HU Rack / 800mm |
Weight |
approx. 400kg |
Application |
Suitable for testing Hybrid and E-vehicles |
CNI 503A2.1, 5.5KV |
Three-phase CDN |
according to EN/IEC 61000-4-4 and EN/IEC 61000-4-5 for Burst up to 5.5kV Surge up to 5kV |
EUT supply |
3x690V, 32A AC |
Dimensions Size |
19"" / 6 HU |
Weight |
approx. 37kg |
CNI 503A3, 5.5KV |
Three-phase CDN |
according to EN/IEC 61000-4-4 and EN/IEC 61000-4-5 for Burst up to 5.5kV Surge up to 5kV |
EUT supply |
3x480V, 63A AC |
Dimensions Size |
19"" / height depending on the size of the rack |
Weight |
approx. 100kg |
CNI 503A3.2, 5.5KV |
Three-phase CDN |
according to EN/IEC 61000-4-4 and EN/IEC 61000-4-5 for Burst up to 5.5kV Surge up to 5kV |
EUT supply |
3x690V, 63A AC |
Dimensions Size |
19"" / height depending on the size of the rack |
Weight |
approx. 100kg |
CNI 503A4.1, 5.5KV |
Three-phase CDN |
according to EN/IEC 61000-4-4 and EN/IEC 61000-4-5 for Burst up to 5.5kV Surge up to 5kV |
EN 50121-x couplings |
manual selectable for 42 ohm, 0.5 uF, 12 ohm, 9 uF |
EUT supply |
3x480V, 100A AC |
Dimensions Size |
19"" / height depending on the size of the rack |
Weight |
approx. 30 kg |
CNI 503A4.2, 5.5KV |
Three-phase CDN |
according to EN/IEC 61000-4-4 and EN/IEC 61000-4-5 for Burst up to 5.5kV Surge up to 5kV |
EUT supply |
3x690V, 100A AC |
Dimensions Size |
19"" / height depending on the size of the rack |
Weight |
approx. 100kg |
CNI 503A S23, 5.5KV |
Three-phase CDN |
according to EN/IEC 61000-4-4 and EN/IEC 61000-4-5 for Burst up to 5.5kV Surge up to 5kV |
EUT supply |
3x690V, 200A AC
1,000V, 200A DC |
Dimensions Size |
19"" / height depending on the size of the rack |
Weight |
approx. 150kg |
GENERAL DATA |
COUPLING MODES |
IEC 61000-4-4 |
Line(s) to Reference Ground; all combinations |
IEC 61000-4-5 |
Line to Line with a 2ohm source impedance Line(s) to PE with a 12ohm source impedance |
ANSI/IEEE C62.4 |
(supporting models only)
Surge coupling with a 2ohm source impedance for all lines |