TECHNICAL DETAILS |
VOLTAGE SURGE SIMULATOR, PULSE 1.2/50US AS PER EN/IEC 60255-5 |
TECHNICAL DATA |
Voltage (o.c.) |
250V - 15,000V ± 10% |
Front time |
1.2µs ± 30% |
Time to half value |
50µs ± 20% |
Source impedance |
500ohm |
Energy |
0.5J ± 0.05J at each test level |
Test level |
0.55kV, 0.9kV, 3.00kV, 5.0kV, 6.6kV, 9.3kV and 14kV |
Pulse forming |
As per IEC 60255-5 |
Polarity |
Positive, negative or alternating |
Event counter |
1 - 30,000 or endless |
TRIGGER |
Trigger of events |
Automatic, manual, external |
CRO trigger |
5V trigger signal for oscilloscope |
Synchronization |
0° - 360°, resolution 1° |
Repetition rate |
1s - 999s, depending on the voltage |
OUTPUT |
Direct |
Via HV connector; Zi = 500ohm
To connect external test boxes or devices |
Output 1 |
500V - 6,600V |
Output 2 |
6,600 - 15,000V |
INTERFACE |
Serial interface |
USB |
Parallel interface |
IEEE 488, addresses 1 to 30 |
GENERAL DATA |
Dimensions |
19""/6HU |
Weight |
approx. 25kg |
Supply voltage |
115/230V +10/-15% |
Fuses |
2xT2AT (230V) or 2xT4AT (115V) |