TECHNICAL DETAILS |
vsurge NX20 - 1.2/50 US SURGE GENERATOR |
VOLTAGE PULSE |
Voltage (open circuit) |
800 V to 20,000 V +/-10 % |
Front time |
1.2 μs +/-30 % |
Time to half value |
50 μs +/-20 % |
Pulse shaping networks |
Depending on load capacitance |
Capacitance ranges |
20 nF to 170 nF in 11 ranges,
manual selectable,
20 nF to 25 nF,
25 nF to 30 nF,
30 nF to 35 nF,
35 nF to 40 nF,
40 nF to 50 nF,
50 nF to 60 nF,
60 nF to 75 nF,
75 nF to 95 nF,
95 nF to 115 nF,
115 nF to 140 nF,
140 nF to 170 nF |
Wave Shape |
As per IEC 60060-1 |
Polarity |
Positive/negative, manual |
Event counter |
1 to 99,999, selectable |
OUTPUT |
Direct |
Via coaxial HV connector |
|
Direct connection to the EUT or via external test box PCV AD1 |
INTERFACE |
Serial interface |
2 x USB A for memory stick,
1 x USB B for service only,
Opto - Link to USB for remote |
Lan |
Ethernet for remote |
Sys. link |
26 pin high density connector to control an external coupling network |
Fail inputs |
EUT monitoring via input (one each)
EUT Monitor 1
EUT Monitor 2 |
GENERAL DATA |
Dimensions, weight |
19""/9 HU, 448 x 442 x 550 mm,
approx. 25 kg |
Supply voltage |
85 V - 264 VAC |
Fuses |
115 V: 2 x 4 A slow blow,
230 V: 2 x 2 A slow blow |
Power max. |
95 W, 0.42 A,
avg. 35 W, 0.15 A |