| SURGE TEST MODE |
| Coupling mode |
shielded and unshielded cable with up to 4 pairs |
| Test voltage |
Max. 3kV* (1.2/50us) (* only with connected RJ45
Connector; if left open the max. test voltage is limited to 1.5kV) |
| Residual voltage |
Max. 40V @2kV Surge, line - PE |
| RINGWAVE TEST MODE |
| Coupling mode |
shielded and unshielded cable with up to 4 pairs |
| Test voltage |
Max. 3kV* (0.5us/100kHz) (* only with connected RJ45 Connector; if left open the max. test voltage is limited to 1.5kV) |
| Residual voltage |
Max. 40V @2kV Ringwave, line - PE |
| BURST TEST MODE |
| Coupling mode |
shielded and unshielded cable with up to 4 pairs |
| Test voltage |
Max. 4kV* (5/50ns) (* only with connected RJ45
Connector; if left open the max. test voltage is limited to 1.5kV) |
| Residual voltage |
Max. 40V @2kV Burst, line - PE |
| TELECOM LINE SPECIFICATIONS |
| Input/output |
RJ45 female connectors for telecom lines |
| Terminal layout |
Pair 1: pins 1/2
Pair 2: pins 3/6
Pair 3: pins 4/5
Pair 4: pins 7/8 |
| Data rate |
up to 1,000MBit/s |
| Protection |
+- 60V between two pairs |
| Operating voltage |
Max. 57VDC |
| Operating current |
Max. 1A |
| INPUTS |
| Surge/Ringwave shield |
SHV connector |
| Surge/Ringwave unshielded |
SHV connector |
| Burst |
SHV connector |
| GENERAL DATA |
| Dimensions |
270mm x 110mm x 140mm (LxWxH) |
| Weight |
6.5kg |
| Temperature |
5°C - 40°C (operation) |
| Rel. humidity |
10% - 90%, non condensing |