solar 2854-1 Transient Generator


For MIL-STD-461F CS106 Conducted Transient Susceptibility Test.

The generator provides 5 μS ±22 %, pulse with a 1.5 μS ± 0.5 μS rise time across a 5.0 ohm non-inductive resistor. Voltage is adjustable to greater than 600 volts. The undershoot is limited to less than 120 volts peak (maximum) and less than 20 μS. The repetition rate is variable and can be adjusted from 0.8 p.p.s. to 10 p.p.s. Single transients can be applied with the pushbutton on the front panel.

Two sets of output terminals allow either parallel or series injection into the power line. The Series injection may be used on D.C. and A.C. lines. Parallel injection should be used on D.C. lines only. The output winding used for series injection can carry 25 amperes of power current. The output terminals are isolated from the chassis and the power cord.