solar 9354-1 Transient Generator
For Susceptibility Tests MIL-STD461C/D/E and Other Specifications. The Model 9354-1 & 9354-2 Transient Generators provide nine selectable waveforms, including six damped sinusoidal pulses (10 KHz,100 KHz, 1 MHz, 10 MHz, 30 MHz, and 100 MHz) and three double exponential pulses (6.4 µS, 70 µS, 500 µS and 120 µS on 9354-2). Auto pulsing of the sinusoidal repetition rate is internally adjusted from 0.5 to 1.0 pulse per second. A front panel-mounted push button can be used to manually trigger single pulses. The peak amplitude of the selected output pulse is adjustable as a percentage of the charge voltage. The six damped sinusoidal waveforms were designed to meet the requirements of MIL-STD-461D and E, method CS116, when applied in accordance with the test method of MIL-STD-462D. Continuous tunable frequencies can be obtained by the use of the optional variable frequency modules. These same waveforms are applicable to the requirements of MIL-STD-461C, methods CS10 and CS11, when applied in accordance with the test method of MIL-STD-462, Notice 5. The 1MHz and 10 MHz damped sinusoidal waveforms have been extended to a peak open circuit voltage of 3200 volts and a calculated short circuit current of 128 amperes to meet the requirements of RTCA DO-160E, Section 22, Table 22-2 and 22-3, waveform 3. The three double exponential pulses were designed to meet the requirements of RTCA DO-160E, Section 22, Tables 22-2 and 22-3.