Wave Shape into 50„¦ load |
Rise time |
5 ns ± 30 % |
Impulse duration |
50 ns ± 30 % |
Wave Shape into 1000„¦ load |
Rise time |
5 ns ± 30 % |
Impulse duration |
50 ns - 15 / + 100 ns |
Burst Characteristic |
Voltage range |
0.22 €¦ 4.8 kV
(0.1 €¦ 4.8 kV in expanded mode) |
Spike frequency |
1 Hz €¦ 1 MHz
(1 Hz €¦ 2 MHz in expanded mode) |
Burst duration |
0.01 €¦ 999 ms |
Burst period |
0.1 Hz €¦ 400 Hz
2.5 ms €¦ 10 s
1 period €¦ 500 periods |
Impulses per second |
Max. 12€™000 |
Impulses per burst |
Max. 1€™000 |
Spike distribution |
normal, continuous, random, real (real5, real100 with “Real
Burst“ option) |
Polarity |
positive, negative |
Test time |
10 s €¦ 8 h per path |
Single Phase Coupling/Decoupling Network |
Maximum AC voltage |
264 V @ 16 €¦ 440 Hz |
Maximum AC current |
16 A @ 50 €¦ 60 Hz, 10 A @ 400 Hz |
Maximum DC voltage |
125 V |
Maximum DC current |
16 A (dependant on DC voltage) |
Coupling Modes |
L-GND, N-GND, PE-GND, LN-GND, LPE-GND, NPEGND, LNPE-GND |
Residual voltage at Test Supply Input |
‰¤ 10% of applied test voltage |
Synchronization |
Frequency |
16 2/3 Hz, 40 Hz, 50 Hz, 60 Hz, 400 Hz, auto |
Impulse trigger |
automatic, manual, external |
System Configuration |
EUT fail input |
BNC, logic low to trigger |
P90 interface |
for a 3-phase CDN extension |
PESD interface |
for connecting an ESD generator |
Printer interface |
Centronix |
Computer interface |
RS-232, IEEE-488 (optional) |
Power Supply |
Voltage |
85 €¦ 264 VAC, 150 VA |
Frequency |
50 / 60 Hz |
Weight and Dimension |
Weight |
14 kg |
W x H x D |
450mm x 130mm x 570mm |