| IMPULSE MODULES | 
| PIM 100 Combination wave impulse module | Built according to IEC/EN 61000-4-5 Ed. 1 & 2 and ANSI C62.41/45 | 
| 1.2/50 μs open circuit up to 7.4 kV | 
| 8/20 μs short circuit up to 3.7 kA | 
| Impulse voltage and current monitors | 
| ± 1° phase synchronization | 
| Reliable semiconductor HV-switch | 
| Positive, negative and alternating polarity | 
| Up to 12 pulses per minute | 
| PIM 110 Ring wave impulse module | Built according to IEC/EN 61000-4-12 and ANSI C62.41/45 | 
| 100 kHz frequency, 0.5 μs rise time | 
| Imp. voltage up to 7.8 kV / 12 Ω, 30 Ω and 200 Ω | 
| Impulse voltage and current monitors | 
| ± 1° phase synchronization | 
| Positive, negative and alternating polarity | 
| Up to 12 pulses per minute | 
| Reliable semiconductor HV-switch | 
| PIM 120 Telecom wave impulse module | Built according to IEC/EN 61000-4-5 Ed. 1 & 2, ITU K-series and IEC 60950 | 
| 10/700 μs open circuit voltage | 
| 5/320 μs short circuit current | 
| Imp. voltage up to 7.4 kV / 15 Ω and 40 Ω | 
| Impulse voltage & current monitors | 
| Reliable semiconductor HV-switch | 
| Positive, negative and alternating polarity | 
| Up to 12 pulses per minute | 
| PCD 120 Four-wire coupling unit for telecom wave | 4 wire coupling unit for unshielded symmetrical operated lines | 
| Compliant with IEC 61000-4-5 (10/700 μs impulse only), ITU K.20 / K.21 / K.44 / K.45 | 
| Fully automated operation | 
| PIM 150 Oscillating wave impulse module | Built according to IEC/EN 61000-4-12 Ed.1, IEC 61000-4-18 Ed.1, IEC 60255-22-1 and ANSI C37.90 | 
| 100 kHz and 1 MHz burst frequencies | 
| 75 ns rise time | 
| Impulse voltage up to 3.3 kV / 200 Ω | 
| Integrated, fully automatic CDN for three-phase AC and DC power lines | 
| EUT mains voltage up to 480 V / 277 V 16 A | 
| Impulse voltage monitor | 
| Capacitive coupling clamp available optionally (IP 4 A) | 
| Data line CDN available optionally (PCD 150) | 
| COUPLING / DECOUPLING NETWORKS | 
| PCD 100 Single phase CDN for combination & ring wave | Built according to IEC/EN 61000-4-5 Edition 1 & 2 ANSI C62.41/45, TIA-968A (FCC part 68/47 CFR), Telcordia (Bellcore) GR 1089 CORE | 
| Fully automated test routines | 
| Coupling of up to two different wave-shapes without any rewiring | 
| For combination wave, ring wave and others (PIM 100, PIM 110) | 
| Up to 8 kV impulse voltage | 
| EUT mains up to 264 V / 16 A | 
| PCD 130 Three phase CDN for combination and ring wave | Built according to IEC/EN 61000-4-5 Edition 1 & 2 ANSI C62.41/45, TIA-968A (FCC part 68/47 CFR), Telcordia (Bellcore) GR 1089 CORE | 
| Fully automated test routines | 
| Coupling of up to three different wave- shapes without any rewiring | 
| For combination wave, ring wave and others | 
| Up to 8 kV impulse voltage | 
| EUT mains voltage up to 690 V / 400 V | 
| EUT mains current up to 32 A per phase | 
| Correct phase angle synchronization for each coupling path |