| OUTPUT CHARACTERISTICS CONTINUOUS MODE |
| Test frequencies |
DC, 16 2/3Hz, 50Hz and 60Hz |
| Signal level |
0.1 - 35 Vrms or DC |
| Test level 1 |
1V continuous |
| Test level 2 |
3V continuous |
| Test level 3 |
10V continuous |
| Test level 4 |
30V continuous |
| Output impedance |
50ohm ± 10% |
| Total harmonics distortion |
< 10% (sinusoidal waveform) |
| Ripple on DC |
< 5% |
| OUTPUT CHARACTERISTICS SHORT-TERM MODE |
| Test frequencies |
DC, 16 2/3Hz, 50Hz and 60Hz |
| Signal level |
1 - 330 Vrms or DC |
| Test level 1 |
10V for 1s duration |
| Test level 2 |
30V for 1s duration |
| Test level 3 |
100V for 1s duration |
| Test level 4 |
300V for 1s duration |
| Output impedance |
50ohm ± 10% |
| Total harmonics distortion |
< 10% (sinusoidal waveform) |
| Phase synchronization |
0° ± 5% |
| Ripple on DC |
< 5% |
| Fall/rise time |
between 1us and 5us |
| Note: |
These tests require either the optional MV 2606N2.2 motor variac or the optional programmable AC voltage source ACS 500N2.3. |
| TESTING AS PER IEC/EN 61000-4-16 OUTPUT CHARACTERISTICS 15Hz - 165kHz |
| Frequency range |
10Hz to 165kHz |
| Signal level |
0.1 to 35 Vrms |
| Test level 1 |
1V - 0.1V - 1V |
| Test level 2 |
3V - 0.3V - 3V |
| Test level 3 |
10V - 1V - 10V |
| Test level 4 |
30V - 3V - 30V |
| Output impedance |
50ohm ± 10% |
| Total harmonics distortion |
< 1% (sinusoidal waveform |
| INTERFACE |
| Serial interface |
USB |
| Parallel interface |
IEEE 488, addresses 1 to 30 |
| Fail 1 |
BNC input; test will be stopped immediately when input becomes active low) |
| Fail 2 |
BNC input; test will be stopped (when input becomes active low) and continued (input active high). After 10 fail events the test will be stopped. |
| GENERAL DATA |
| Dimensions |
19""/6HU 555mm x 448mm x 286mm |
| Weight |
Approx. 30kg |
| Supply voltage |
115V - 230V +10/-15%, 50/60Hz |
| Input power |
Max. 600W |
| Fuses |
2 x 6.3AT (115V) or 2 x 3.15AT (230V)
2 x 10AT for AC-Source |
| Cooling |
Active cooling, air ventilation |
| Temperature |
10°C to 40°C |