TECHNICAL DETAILS |
As per EN/IEC 61000-4-4 and EN 61000-6-1, -6-2 |
Test voltage |
200V - 5,500V ± 10%;
100V - 2,750V ± 10% into 50ohm |
Pulse shape |
5/50ns into 50ohm and 1,000ohm |
Rise time tr |
5ns ± 30% into 50ohm;
5ns ± 30% into 1,000ohm |
Pulse width td |
50ns ± 30% into 50ohm;
50ns -15/+100ns into 1,000ohm |
Source impedance |
50ohm |
Polarity |
Positive/negative |
Output |
|
Direct |
Via 50ohm coaxial connector |
Coupling mode |
L, N, PE; all combinations |
DUT supply |
AC: 300V/16A; 50/60Hz |
|
DC: 300V/16A |
CRO trigger |
5V trigger signal for oscilloscope |
Interface |
Serial interface |
USB |
Parallel interface |
IEEE 488, addresses 1 - 30 |
Analog output |
0 - 10VDC to control an external transformer |
CN interface |
15pin SubD connector to control an external coupling network |
Fail inputs |
DUT monitoring via Fail1 and Fail2 input (one each) |
Dimensions |
Dimensions |
19"", 3HU |
Weight |
approx. 14kg |