As per EN/IEC 61000-4-5 and EN 61000-6-1, -6-2 |
Voltage (o.c.) |
160V - 5,000V ± 10% |
Pulse front time |
1.2us ± 30% |
Pulse time to half value |
50us ± 20% |
Current (s.c.) |
Max. 2,500A ± 10% |
Pulse front time |
8us ± 20% |
Pulse time to half value |
20us ± 20% |
Polarity |
Positive/negative/alternating |
Event counter |
1 - 30,000 or endless, selectable |
OUTPUTS |
Direct |
Via HV connectors for external coupling networks (Zi = 2ohm with optional adapter IMN 2) |
Coupling mode |
Line to line
Line(s) to ground |
DUT supply |
AC: 300V/16A; 50/60Hz
DC: 300V/16A |
CRO trigger |
5V trigger signal for oscilloscope |
Interfaces |
Serial interface |
USB |
Parallel interface |
IEEE 488, addresses 1 - 30 |
CN interface |
15pin SubD connector to control an external coupling network |
Fail inputs |
DUT monitoring via Fail1 and Fail2 input (one each) |
MAINS |
Supply voltage |
115V/230VAC +10%/-15% |
Power |
approx. 75W |
Frequency |
50/60Hz |
Fuses |
2 x T 2AT (230V) or 2 x T 4AT (115V) |