TECHNICAL DETAILS |
COMBINATION WAVE 1.2/50US - 8/20US |
Voltage (o.c.) |
500V - 10,000V ± 10% |
Pulse front time |
1.2μs ± 30% |
Pulse time to half value |
50μs ± 20% |
Current (s.c.) |
Max. 5,000A ± 10% |
Pulse front time |
8μs ± 20% |
Pulse time to half value |
20μs ± 20% |
Polarity |
Positive/negative/alternating |
Event counter |
1 - 30,000 or endless |
TRIGGER |
Trigger of events |
Automatic, manual, external |
CRO trigger |
5V trigger signal for oscilloscope |
Synchronization |
0° - 360°, resolution 1° |
Repetition rate |
6s - 999s, depending on the voltage |
OUTPUT |
Direct |
2 outputs via HV connectors;
- Zi = 2ohm
- for external coupling networks |
INTERFACE |
Optical interface |
Opto link, 3m cable
USB A connector |
Parallel serial interface |
IEEE 488, addresses 1 - 30 |
CN interface |
To control external coupling matrix |
SAFETY |
Safety circuit |
Control input (24Vdc) |
Warning lamp |
Floating output contact |
GENERAL DATA |
Dimensions - Weight |
19""/6HU, approx. 35kg |
Supply voltage |
115/230V +10/-15% |
Fuses |
2x T 2AT (230V) or 2X T 4AT (115V) |