| TECHNICAL DATA |
| RCB 200 |
Circuitry as per Annex G, Figs. G-1 to G-4 with the following components: |
| Inductor 2 |
5 uH inductor (50 amp) (Osborne transformer part no. 8745) |
| Relay 3 |
12 volt AC relay Potter & Brumfield KUP-14A15-12 |
| Inductor 4 |
100 mH inductor @ 1 amp (Osborne transformer part no.32416) |
| Resistor 5 |
6 ohms +/-5% |
| Resistor 6 |
100 ohms +/-5% |
| Switch 7 |
SPST (1 amp). Switch closed for Pulses A1 and C |
| OPERATION |
| TEST |
Start/Stop of the test |
| Pulse |
To select the pulses of the preset test |
| Mode |
To select the mode of generating the pulses |
| INPUTS/OUTPUTS |
| Inputs |
4mm safety lab connectors for DC supply |
| Outputs |
4mm safety lab connectors for CI 220 and CI 260 testing |
| LEDs |
Indicates
- TEST ON status
- Pulse
- Mode |
| GENERAL DATA |
| Dimensions
Weight |
250mm x 160mm x 130mm
Approx. 3.75kg |
| Fuse |
20A for DUT supply current |
| Protection |
Electronically protected against overvoltage and reversed polarity |