| PSURGE 30.2 Mainframe |
| Charging voltage range |
3...33kV |
| Capacitors |
9uF / 36uF |
| Stored energy |
5kJ at max. charging voltage |
| HV output |
terminals inside the test cabinet |
| Power mains |
208, 230 or 240V
50/60Hz, 1800VA |
| HV switch |
triggered spark gap |
| Impulse polarity |
positive, negative, alternating |
| Impulse circuit |
floating, max. voltage between common and ground 500V AC |
| External synchronization |
0°....360° in 1° steps |
| Dimensions (W x D x H) |
| PSURGE 30.2 |
60 x 100 x 190 cm |
| Test cabinet |
39 x 29 x 32 cm |
| Weight |
approx. 320 kg |
| Impulse Module PS30-CW |
| Impulse type |
Combination wave |
| Voltage front time |
1.2us ±30% |
| Voltage decay time |
50us ±20% |
| Voltage undershoot |
‰¤30% |
| Voltage amplitude range |
3...30kV |
| Impulse repetition |
Up to 6 impulses per minute at max. voltage |
| Output impedance |
2 Ohm |
| Current front time |
8us ±20% |
| Current decay time |
20us ±20% |
| Current undershoot |
‰¤30% |
| Current amplitude range |
1.5...15kA |
| Impulse Module PS30-8x20 |
| Impulse type |
Current |
| Voltage front time |
not defined |
| Voltage decay time |
not defined |
| Undershoot |
not defined |
| Charging voltage range |
3...15kV |
| Impulse repetition |
Up to 2 impulses per minute at max. current |
| Output impedance |
0.5 Ohm |
| Current front time |
8us ±20% |
| Current decay time |
20us ±20% |
| Undershoot |
‰¤20% |
| Current amplitude range |
6...30kA |
| Impulse Module PS30-10x350 |
| Impulse type |
current |
| Voltage front time |
not defined |
| Voltage decay time |
not defined |
| Charging voltage range |
3...15kV |
| Impulse repetition |
Up to 2 impulses per minute at max. current |
| Output impedance |
12 Ohm |
| Current front time |
10us ±20% |
| Current decay time |
350us ±20% |
| Current amplitude range |
240...1200A |
| Impulse Module PS30-10x1000 |
| Impulse type |
Current |
| Voltage front time |
not defined |
| Voltage decay time |
not defined |
| Charging voltage range |
3...15kV |
| Impulse repetition |
Up to 2 impulses per minute at max. current |
| Output impedance |
37 Ohm |
| Current front time |
10us ±20% |
| Current decay time |
1000us ±20% |
| Current amplitude range |
80...400A |
| Coupling and decoupling network FP-SURGE 3010 |
| Impulse shape |
Combination wave only |
| EUT line voltage |
480V AC
110V DC |
| EUT current |
10A |
| Imp. amplitude |
30kV / 15kA |
| Coupling modes |
Line to neutral
Line or neutral to ground
Line and neutral to ground |
| Coupling capacitors |
2x9uF / 1x18uF |
| Residual voltage at EUT line input |
15% of the applied test voltage, limited to approx. 1200V |
| Dimensions (W x D x H) |
| FP-SURGE 3010 |
60 x 100 x 190 cm |
| Test cabinet |
40 x 40 x 80 cm |
| Weight |
| FP-SURGE 3010 |
approx. 250 kg |