RATED POWER OUTPUT
|
1000 watts minimum
|
INPUT FOR RATED OUTPUT
|
1.0 milliwatt maximum
|
POWER OUTPUT @ 3dB COMPRESSION
|
Nominal
|
950watts
|
Minimum
|
900 watts
|
POWER OUTPUT @ 1dB COMPRESSION
|
Nominal
|
800 watts
|
Minimum
|
700 watts
|
AVERAGE OUTPUT POWER @ 3.2 GHz AND ABOVE
|
Less than 60 watts
|
FLATNESS
|
±1.5 dB typical
±2.0 dB maximum
|
FREQUENCY RESPONSE
|
1.0-2.5 GHz instantaneously
|
GAIN (at maximum setting)
|
60 dB minimum
|
GAIN ADJUSTMENT (Continuous Range)
|
20 dB minimum (4096 steps remote)
|
INPUT IMPEDANCE
|
50 ohms, VSWR 2.0:1 maximum
|
OUTPUT IMPEDANCE
|
50 ohms, nominal
|
MISMATCH TOLERANCE
|
100% of rated power without foldback. Will operate without damage or oscillation with any magnitude and phase of source and load impedance.
|
MODULATION CAPABILITY
|
Will faithfully reproduce AM, FM, or pulse modulation appearing on the input signal
|
HARMONIC DISTORTION
|
Minus 20 dBc maximum at 700 watts
|
THIRD ORDER INTERCEPT POINT
|
69 dBm typical
|
NOISE FIGURE
|
10 dB typical
|
SPURIOUS
|
Minus 73 dBc typical
|
PHASE LINEARITY
|
±1.0 deg/100 MHz, typical
|
PRIMARY POWER
(selected automatically)
|
200-264 VAC
50/60 Hz, single phase
4500 watts maximum
|
CONNECTORS
|
RF INPUT
|
Type N female on front panel
|
RF OUTPUT
|
Type 7/8 EIA female
|
REMOTE INTERFACES
|
IEEE-488
|
24 pin female
|
RS-232
|
9 pin Subminiature D
|
RS-232 (Fiber-optic)
|
Type ST
|
USB 2.0
|
Type B
|
Ethernet
|
RJ-45
|
SAFETY INTERLOCK
|
15 Pin Subminiature D
|
COOLING
|
Forced air (self contained fans)
|
SIZE (W x H x D)
|
50.3 x 127 x 61cm, 19.8 x 50 x 24 in
|
WEIGHT (approximate)
|
148 kg (325 lbs)
|