RATED POWER OUTPUT
|
1900 watts minimum
|
INPUT FOR RATED OUTPUT
|
1.0 milliwatt maximum
|
POWER OUTPUT @ 3dB compression
|
Nominal
|
2100 watts
|
Minimum
|
1700 watts
|
POWER OUTPUT @ 1dB compression
|
Nominal
|
1750 watts
|
Minimum
|
1250 watts
|
FLATNESS
|
±2.5 dB
±0.8 dB with internal leveling
|
FREQUENCY RESPONSE
|
80 MHz-1000 MHz instantaneously
|
GAIN (at maximum setting)
|
63 dB minimum
|
GAIN ADJUSTMENT (Continuous Range)
|
18 dB minimum
|
INPUT IMPEDANCE
|
50 ohms, VSWR 2.0:1 maximum
|
OUTPUT IMPEDANCE
|
50 ohms, nominal
|
MISMATCH TOLERANCE
|
100% of rated power without foldback up to 6.0:1 mismatch above with may limit to 1000 watts. Will operate without damage or oscillation with any magnitude and phase of source and load impedance.
|
MODULATION CAPABILITY
|
Will faithfully reproduce AM, FM, or pulse modulation appearing on the input signal
|
HARMONIC DISTORTION
|
Minus 20 dBc maximum at 1600 watts
|
THIRD ORDER INTERCEPT POINT
|
70 dBm typical
|
RF POWER METER
|
0-2500 watts full scale
|
PRIMARY POWER (specify voltage)
|
200-250 VAC, Delta Connected (4 wire)
360-435 VAC, Wye Connected (5 wire)
50/60 Hz, three phase
25 kVA maximum
|
REMOTE INTERFACES
|
IEEE-488 & RS-232 connector on rear panel
|
CONNECTORS
|
RF input
|
Type N female, rear panel
|
RF output
|
Type 1 5/8 EIA, rear panel
|
External Leveling Inputs
|
Type BNC female on front panel
|
Pulse Modulation Input
|
Type BNC female on front panel
|
Detected RF Output
|
Type BNC female on front panel
|
Remote Computer Interface
|
24 Pin female IEEE-488 (GPIB) and RS-232 connector on rear panel
|
Remote Computer Interface (fiber optic)
|
ST Conn Tx and Rx RS-232
|
Safety Interlock
|
15 pin female Type D on rear panel
|
COOLING
|
Forced air (self contained fans), enters front and bottom
|
SIZE (W x H x D) (3 cabinets)
|
201 x 158 x 160 cm, 79 x 62 x 63 in.
|
WEIGHT
|
839 kg (1850 lb)
|