| CD mode |
500V - 10,000V +/-5% |
| AD mode |
500V - 16,500V +/-5% |
| Resolution |
100V steps |
| Holding time |
More than 5 seconds |
| Polarity |
Positive, negative |
| Test voltage |
measured, indicated in the display |
| Single mode |
Release of single pulses |
| Continuous mode |
Continuous discharge up to
20Hz (AD) and 10Hz (CD) |
| Pulse release via software |
Remote control from computer via fiber optic link (USB) |
| CD mode |
EN/IEC 61000-4-2; 150pF/330ohm |
| Rise time |
0.8ns +/- 25% |
| Current 1st peak |
7.5A +/- 15% @2kV
15.0A +/- 15% @4kV
22.5A +/- 15% @6kV
30.0A +/- 15% @8kV |
| Current at 30ns |
4.0A +/- 30% @2kV
8.0A +/- 30% @4kV
12.0A +/- 30% @6kV
16.0A +/- 30% @8kV |
| Current at 60ns |
2.0A +/- 30% @2kV
4.0A +/- 30% @4kV
6.0A +/- 30% @6kV
8.0A +/- 30% @8kV |
| Weight |
940 grams incl. battery |
| Case material |
ABS; non-inflammable as per UL 94VO |
| Temperature |
5°C - 40°C (operation conditions) |
| Rel. humiditiy |
20% - 80% (operation conditions) |
| Battery charger |
100V - 240V +/-10%; 50/60Hz
Charging time less than 1.5 hours |