LOAD DUMP GENERATOR |
PULSE SPECIFICATION |
Voltage (o.c.) |
20V - 200V ± 10% |
ISO PULSE 5 AND 7 |
Rise time |
5ms - 10ms (10 - 90%) |
Pulse duration |
40 - 400ms (10 - 10%) |
Int. resistor |
0.5ohm - 38ohm, selectable in steps of 0.1ohm |
Repetition rate |
Min. 30s |
SAE J1455 FOR 12V BATTERY SUPPLY |
Voltage (o.c.) |
+86V ± 10% |
Rise time |
100us (10% - 90%) |
Pulse duration |
400ms ± 10% (10 - 10%) |
Int. resistor |
0.4ohm |
SAE J1455 FOR 24V BATTERY SUPPLY |
Voltage (o.c.) |
+122V ± 10% |
Rise time |
100us |
Pulse duration |
400ms ± 10% (10 - 10%) |
Int. resistor |
0.8ohm |
JASO PULSE A1 |
Voltage (o.c.) |
+70V ± 10% |
Rise time |
1us (10% - 90%) |
Pulse duration |
200ms ± 10% (measured at tau) |
Int. resistor |
0.8ohm |
Capacitor |
110mF |
JASO PULSE B1 (FIELD DECAY) |
Voltage (o.c.) |
-80V ± 10% |
Rise time |
1us (10% - 90%) |
Pulse duration |
60ms (measured at tau) |
Int. resistor |
8ohm |
Capacitor |
3mF |
LOAD DUMP GENERATOR |
JASO PULSE D1 |
Voltage (o.c.) |
+110V ± 10% |
Rise time |
1us (10% - 90%) |
Pulse duration |
400ms (measured at tau) |
Int. resistor |
1.5ohm |
Capacitor |
73mF |
CHRYSLER PF 9326 PULSE 5 |
Voltage (o.c.) |
+91.5V ± 10% |
Rise time |
5 - 10ms (10% - 90%) |
Pulse duration |
300ms td (10 - 10%) |
Loaded pulse |
+45.75V ± 10% into a 0.5ohm load |
Pulse duration |
> 95ms (10 - 10%) |
Int. resistor |
0.5ohm |
Repetition rate |
120s |
FORD ES-XW7T CI 240 (AB-VERSION) |
Voltage (o.c.) |
60V ± 10% |
Rise time |
1 - 10ms (10% - 90%) |
Pulse duration |
300ms (10% - 10%) |
Voltage (loaded) |
30V ± 10% into a 0.7ohm load |
Pulse duration |
150ms ± 10% (10 - 10%) |
Int. resistor |
0.5ohm |
Repetition rate |
3 pulses every 30s |
FORD ES-XW7T CI 220G (AC-VERSION) |
Voltage (o.c.) |
60V ± 10% |
Rise time |
1 - 10ms (10% - 90%) |
Pulse duration |
300ms (10% - 10%) |
Voltage (loaded) |
30V ± 10% into a 0.5ohm load |
Pulse duration |
150ms ± 10% (10 - 10%) |
Int. resistor |
0.5ohm |
Repetition rate |
3 pulses every 30s |
GENERAL DATA |
DIMENSIONS AND WEIGHT |
Dimensions |
19""/6HU, 500mm x 450mm x 290mm |
Weight |
approx. 25kg |
Supply voltage |
115V/230V +10%/-15% |
Fuses |
2x T2AT (230V) or 2x T4AT (115V) |
OUTPUT |
+/- output |
Safety laboratory connectors |
Coupling |
To the battery +line |
Decoupling |
Via diode |
DUT supply |
Max. 60V/30A |
INTERFACE |
Serial interface |
USB |
Parallel interface |
IEEE 488, addresses 1 - 30 |
CN interface |
To control external CN - UCS 200N |
OPTIONS |
iso.control |
Software to control the test, including standard library, test report facility and data conversion generator |
CA ISO |
Pulse verification set for Micropulse and load dump pulse verification |