TECHNICAL DATA PFS 200N50 |
DUT voltage |
Max. 80V for channels PF1/PF2 |
DUT current |
Max. 50A for channels PF1/PF2 |
Switching time |
1us (rise/fall time) |
Peak current |
100A for 500ms |
Safety |
Short circuit protection |
TRIGGER |
Automatic |
Automatic release of the events |
Repetition rate |
100ms to 999s |
Dip/drop duration td |
1us to 10s |
Manual |
Manual release of a single event |
CRO Trigger |
Trigger for oscilloscope, +15V edge |
External |
External release of a single event |
TEST ROUTINES |
Quick Start |
Immediate start; easy-to-use and fast |
Chrysler |
Voltage Drop Out
Voltage Dig
Mechanical Switching |
Ford |
Drop Out High
Drop Out Low
Drop Out Single
Power Dip |
RSA/Renault |
Micro interruptions |
Service |
Service, setup, self-test |
GENERAL DATA |
Dimensions, Weight |
19""/3HU approx. 15kg;
19""/6HU, approx. 18kg for PFS 200N150 and PFS200N200 |
Supply voltage |
115V/230V +10/-15% |
Fuses |
2 x T 1AT |
INTERFACE |
Interface |
USB |
Parallel interface |
IEEE 488, addresses 1 to 30 |
Analog interface |
OVdc to 10Vdc to control an external dc source (e.g. RDS 200N) |