VDS 200Q100 |
Output Range |
-15 V - +30 V / +60 V |
Output current |
0 A - 100 A, continuous |
Peak current |
300 A for 200 ms |
Bandwidth |
DC - 150 kHz full signal |
Supply Voltage |
3-phase 200/400 V ±10%, L1, L2, L3, PE |
Dimensions |
19""/38 HU |
Weight |
450 kg |
COMMON DATA (ALL MODELS) |
GENERAL |
Source impedance |
Zi = <10 mohm |
Operation |
4 - quadrant, bipolar operation |
Current limiter |
(not available for VDS 200Q10) 3x Imax: allows an inrush current of three times nominal current for 200 ms before the current limiter starts 3x ictrl: allows an inrush current of three times the programmed current for 200 ms before the current limiter starts Peak OFF: no inrush current above the set current value |
Compensation |
STD: DC - 40 kHz
HF: DC - >=150 kHz
CAP: DC - 3kHz |
Recovery |
>90% of excursion within 25 us |
Output rise time |
typ. <10 us, <3 us (high freq.) |
Ripple voltage |
Ur <10 mVp-p, frequency min. 400 Hz |
Control |
Analog In |
Cooling |
temperature-controlled air cooling |
Protection |
Thermal-Magnetic Circuit Breakers Depending on VDS 200Q model |
TRIGGER |
Automatic |
Automatic release of the events |
Manual |
Manual release of a single pulse |
External |
External release of a single pulse |
OUTPUT |
DUT Supply +/- |
Safety laboratory or high current connectors |
Ext. trigger |
5-15 V TTL, BNC connector |
CRO Trigger |
5 V TTL-signal for oscilloscope |
INTERFACE |
Interfaces |
USB
Ethernet (for optional AutoWave)
IEEE 488, addresses 1 - 30 |
Remote control |
To connect an external signal generator (10 kohm): -10 V - +10 V / 0 - 150 kHz (180 kHz for VDS 200Q10) |