| GENERAL |
| Source impedance |
Zi = <10 mohm |
| Operation |
4 - quadrant, bipolar operation |
| Current limiter |
(not available for VDS 200Q10) 3x Imax: allows an inrush current of three times nominal current for 200 ms before the current limiter starts 3x ictrl: allows an inrush current of three times the programmed current for 200 ms before the current limiter starts Peak OFF: no inrush current above the set current value |
| Compensation |
STD: DC - 40 kHz
HF: DC - >=150 kHz
CAP: DC - 3kHz |
| Recovery |
>90% of excursion within 25 us |
| Output rise time |
typ. <10 us, <3 us (high freq.) |
| Ripple voltage |
Ur <10 mVp-p, frequency min. 400 Hz |
| Control |
Analog In |
| Cooling |
temperature-controlled air cooling |
| Protection |
Thermal-Magnetic Circuit Breakers Depending on VDS 200Q model |
| TRIGGER |
| Automatic |
Automatic release of the events |
| Manual |
Manual release of a single pulse |
| External |
External release of a single pulse |
| OUTPUT |
| DUT Supply +/- |
Safety laboratory or high current connectors |
| Ext. trigger |
5-15 V TTL, BNC connector |
| CRO Trigger |
5 V TTL-signal for oscilloscope |
| INTERFACE |
| Interfaces |
USB
Ethernet (for optional AutoWave)
IEEE 488, addresses 1 - 30 |
| Remote control |
To connect an external signal generator (10 kohm): -10 V - +10 V / 0 - 150 kHz (180 kHz for VDS 200Q10) |