GENERAL SWITCH |
Switch Impedance |
Power lines: < 50 mOhm
Data lines: < 500 mOhm |
Internal switch |
Short circuit switch (DC+ to DC-), impedance <100 mOhm) |
Internal switch |
100 mOhm, per LV 124 |
Internal switch |
Low |
Internal switch |
High |
POWER LINE SWITCH |
Switch |
2 Switches in the circuit
- DC+ Power line
- DC- Ground line |
DUT voltage |
± 100 VDC |
DUT current |
100 mA to 100 A, 200 A @ 25 °C |
Current direction |
Bi-directional |
Switching time |
< 200 ns (rise/fall time) |
Repetition rate |
10 μs - 1 h |
Drop duration |
1 μs - 1 h |
Peak current |
400 A for 200 ms
1,350 A for 1 ms
automatic switch-off if I > 1,350 A |
Safety |
Short circuit protection |
SWITCH FOR SIGNAL- AND DATALINE SWITCH |
Channels |
16 in depend switched lines |
DUT voltage |
Max. ± 40 VDC |
DUT current |
100 μA to 2 A, per channel @ 25 °C |
Current direction |
Bi-directional |
Switching time |
< 1 μs (rise/fall time) |
Repetition rate |
500 μs - 1 h |
Drop duration |
1 μs - 1 h |
Bandwidth |
50 MHz / 3 dB |
Peak current |
5 A for 200 ms |
Safety |
Short circuit protection |
Connector |
PHOENIX, DFMC connector, 1.5 mm2, Push-in-spring cage connection |
INTERFACE |
Frame bus |
Control cable to AutoWave |
Monitor Output |
DUT out, differential, BNC plug on front panel
Ratio 1:20 |
GENERAL DATA |
Dimensions |
19""/3 HU, 448 mm x 536 mm x 154 mm |
Weight approx. |
10.5 kg |
Supply voltage |
100 V - 265 VAC, 50/60 Hz |
Fuses |
2 x 2 AT |
Reference temperature |
23 °C ±5 °C |
Temperature |
10 °C to 35 °C |
Humidity |
25 % to 75 %, non-condensing |
Atmospheric pressure |
86 kPa (860 mbar) to 106 kPa (1 060 mbar) |