| ELECTRICAL FAST TRANSIENTS |
| BURST MODULE |
As per IEC/EN 61000-4-4 and EN 61000-6-1, -6-2 |
| COMBINATION WAVE / SURGE |
| SURGE MODULE |
As per IEC/EN 61000-4-5 and IEC/EN 61000-6-1, -6-2 |
| POWER FAIL, DIPS & INTERRUPTIONS, VOLTAGE VARIATIONS |
| POWER FAIL MODULE |
As per IEC/EN 61000-4-11, IEC/EN 61000-4-29 and IEC/EN 61000-6-1, -6-2 |
| RINGWAVE |
|
| RINGWAVE MODULE |
As per ANSI/IEEE C62.41 and IEC/EN 61000-4-12 |
| GENERAL DATA |
| INTERFACES |
| Serial interface |
2 x USB A for memory stick
1 x USB B for service only
Opto - Link to USB for remote |
| Lan |
Ethernet for remote |
| Analog output |
0 - 10 VDC to control an external transformer |
| Sys.link |
26 pin high density connector to control an external coupling network |
| Fail inputs |
EUT monitoring via input (one each)
EUT Monitor 1
EUT Monitor 2 |
| Ext. Trigger |
BNC Ext. Trigger IN
pos slope 5 V |
| Ext. Sync Input |
Differential input
50 V - 690 VAC
2 x 4 mm MC Safety connectors |
| DIMENSIONS AND WEIGHT |
| 16 A models |
19""/3 HU, 500 mm deep,
19“/9 HU with telecom module, approx. 30 kg |
| 32 A models |
19""/6 HU, 500 mm deep,
19“ 9 HU with telecom module, approx. 40 kg |
| MAINS |
| Supply voltage |
85 V - 264 V |
| Frequency |
50/60 Hz |
| Power |
approx. 75 W |
| Fuses |
115 V: 2 x 4 A slow blow
230 V: 2 x 2 A slow blow |