| COMMON DATA (ALL MODELS) | 
| GENERAL | 
| Source impedance | Zi = <10mohm | 
| Voltage deviation | <1V with resistive load (including inrush current) recovering 63% of its maximum excursion within 100us | 
| Ripple voltage | Ur <0.2Vp-p, frequency min. 400Hz | 
| Sinusoidal signal capability vs. Frequency *) | Vpp max. 16V up to 20kHz
Vpp max. 10V up to 30kHz
Vpp max. 6V up to 50kHz | 
| *) | Vpp max. 3V up to 100kHz via Analog In, controlled by
AutoWave/AMP 200Nx only | 
| Fuses | Depending on VDS 200N model | 
| OUTPUT | 
| DUT Supply +/- | Safety laboratory or high current connectors | 
| Ext. Trigger | 5-15V TTL; BNC connector | 
| CRO Trigger | 5V TTL - signal for oscilloscope | 
| TEST ROUTINES FOR ARBITRARY WAVES | 
| DC source | Max. 60V; current depending on VDS 200N model | 
| Functions | Sine Wave Sweep
Sine Wave (Cranking)
Clipped Load Dump
Jump Start
Extern
GM 9105P Pulse 4
Drop and Jump pulse | 
| Standard Test routines | ISO 7637, Pulses 2b and 4
ISO 16750-2
JASO Test 1 | 
| Service | Service, Setup, Self-test | 
| INTERFACE | 
| Serial interface | USB | 
| Parallel interface | IEEE 488, addresses 1 - 30 | 
| Remote control | To connect an external signal generator (10kohm): 0-10V / 0-50kHz Max.
0.5V(p-p) / 0-100kHz |