| VDS 200Q100 | 
| Output Range | -15 V - +30 V / +60 V | 
| Output current | 0 A - 100 A, continuous | 
| Peak current | 300 A for 200 ms | 
| Bandwidth | DC - 150 kHz full signal | 
| Supply Voltage | 3-phase 200/400 V ±10%, L1, L2, L3, PE | 
| Dimensions | 19""/38 HU | 
| Weight | 450 kg | 
| COMMON DATA (ALL MODELS) | 
| GENERAL | 
| Source impedance | Zi = <10 mohm | 
| Operation | 4 - quadrant, bipolar operation | 
| Current limiter | (not available for VDS 200Q10) 3x Imax: allows an inrush current of three times nominal current for 200 ms before the current limiter starts 3x ictrl: allows an inrush current of three times the programmed current for 200 ms before the current limiter starts Peak OFF: no inrush current above the set current value | 
| Compensation | STD: DC - 40 kHz
HF: DC - >=150 kHz
CAP: DC - 3kHz | 
| Recovery | >90% of excursion within 25 us | 
| Output rise time | typ. <10 us, <3 us (high freq.) | 
| Ripple voltage | Ur <10 mVp-p, frequency min. 400 Hz | 
| Control | Analog In | 
| Cooling | temperature-controlled air cooling | 
| Protection | Thermal-Magnetic Circuit Breakers Depending on VDS 200Q model | 
| TRIGGER | 
| Automatic | Automatic release of the events | 
| Manual | Manual release of a single pulse | 
| External | External release of a single pulse | 
| OUTPUT | 
| DUT Supply +/- | Safety laboratory or high current connectors | 
| Ext. trigger | 5-15 V TTL, BNC connector | 
| CRO Trigger | 5 V TTL-signal for oscilloscope | 
| INTERFACE | 
| Interfaces | USB
Ethernet (for optional AutoWave)
IEEE 488, addresses 1 - 30 | 
| Remote control | To connect an external signal generator (10 kohm): -10 V - +10 V / 0 - 150 kHz (180 kHz for VDS 200Q10) |