| ELECTRICAL FAST TRANSIENTS |
| BURST MODULE |
As per IEC/EN 61000-4-4 and EN 61000-6-1, -6-2 |
| COMBINATION WAVE / SURGE |
| SURGE MODULE |
As per IEC/EN 61000-4-5 and IEC/EN 61000-6-1, -6-2 |
| POWER FAIL, DIPS & INTERRUPTIONS, VOLTAGE VARIATIONS |
| POWER FAIL MODULE |
As per IEC/EN 61000-4-11
IEC/EN 61000-4-29
IEC/EN 61000-6-1, -6-2 |
| TELECOM SURGE |
| TELECOM SURGE MODULE |
| Test voltage |
160 V - 5,000 V ± 10 % |
| Energy storage capacitor |
20 µF |
| Polarity |
Positive, negative, alternating |
| TELECOM SURGE PULSES |
As per IEC/EN 61000-4-5, ITU, ETSI and FCC Part 68 Pulse B |
| GENERAL DATA |
| INTERFACES |
| Serial interface |
2 x USB A for memory stick
1 x USB B for service only
Opto - Link to USB for remote |
| Lan |
Ethernet for remote |
| Analog output |
0 - 10 VDC to control an external transformer |
| Sys.link |
26 pin high density connector to control an external coupling network |
| Fail inputs |
EUT monitoring via input (one each)
EUT Monitor 1
EUT Monitor 2 |
| Ext. Trigger |
BNC Ext. Trigger IN
pos slope 5 V |
| Ext. Sync Input |
Differential input
50 V - 690 VAC
2 x 4 mm MC Safety connectors |
| DIMENSIONS AND WEIGHT |
| 16 A models |
19""/6 HU, 500 mm deep, approx. 30.7 kg |
| 32 A models |
19""/9 HU, 500 mm deep, approx. 40 kg |
| MAINS |
| Supply voltage |
85 V - 264 V |
| Frequency |
50/60 Hz |
| Power |
approx. 75 W |
| Fuses |
115 V: 2 x 4 A slow blow
230 V: 2 x 2 A slow blow |